The following issues were resolved in ExtremeXOS 16.2.4-Patch1-8. ExtremeXOS 16.2.4-Patch1-8 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, ExtremeXOS 16.2.3, and ExtremeXOS 16.2.4. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2.4-Patch1-8
CR Number Description
General
xos0070592 OSPF neighborship is not re-established after configuring IP multicast forwarding option to-cpu to off, and then back on, over the LAG port in VLAN.
xos0070819 Information about PSU fan airflow direction needs to be added to the show power command.
xos0070993

The STP port link-type configuration is not retained when a untagged port is deleted from a VLAN that is part of an STP domain and then added in another

VLAN that is also part of the STP domain. This results in the port behaving like a normal STP port, even though the configuration appears in the output of the show configuration stpd command.

xos0071030 “Ingress Block Port” list is not updated in the kernel for MLAG sharing port after reboot.
xos0071076 The command configure tacacs timeout does not take effect.
xos0071077 The "tag" match condition is not working with BGP routing policies.
xos0071135 Service VMAN packets are being forwarded in slowpath after deleting VPLS instance.
xos0071248 Source MAC address is re-added on PSTAG ports when switch is software learning.
xos0071340 In the output of show mvrp ports counters event command, MVRP LeaveAll Tx packets appear as Rx packets.
xos0071450 In the output of show ports command, the usual expression for excluding “0” entries is not working as expected.
xos0071468 In WMLAG, static MAC address of second peer is not flushed from FDB table during failures.
xos0071532 EDP process ends unexpectedly with signal 6 when receiving EDP packets with zero length on the TLV.
xos0071607 Memory leak for process hal occurs after executing command debug hal show forwarding distribution.
xos0071730 BFD enabled warning message appears when BFD is re-configured, even though it is already enabled.
xos0071107 Uptime is reset after the first failover, but generally is not reset after subsequent failovers.
xos0071783 STP process ends unexpectedly with signal 11 when disabling active link to trigger Backup root.
xos0071745 Multicast packets are dropped for some sources when the route to the source network changes.
SummitStack
xos0070018 In the command show checkpoint-data output, need to show IPML connection status between master and backup in a stack.
xos0071254 Login issues occur when using Telnet to connect to other slots from master node with RADIUS mgmt-access enabled.
xos0071781 New BFD sessions created after stack failover remain in down/initial state if BFD flaps occur prior to failover.
BlackDiamond 8000 Series Switches
xos0070935 With sys-recovery-level set as "shutdown," MSM and I/O modules are not rebooting immediately.
Summit X440 Series Switches
xos0071339 On Summit X440-24t-10G switches, the output of the show fan command displays fan state as "Failed" when RPM is 0.