The following issues were resolved in ExtremeXOS 16.2.3-Patch1-3. ExtremeXOS 16.2.3-Patch1-3 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, and ExtremeXOS 16.2.3. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0065946 | SNMP get for lldpRemSysCapSupported MIB returns incorrect value. |
xos0066477 | Creating a VLAN starting with "vr" causes syntax recognition problems with the show iparp vr command. |
xos0066557 | Kernel crash occurs after removing a subVLAN from one VR and adding the same subVLAN in another VR. |
xos0066775 | Configured peer group capabilities and policies are not reflected after creating a new BGP neighbor. |
xos0066932 | Actual/configured sFlow sample rates are different after reconfiguring. |
xos0066996 | ESRP does not update the neighbor state properly while becoming master from neutral state. |
xos0067002 | UPM status is "fail" if UPM profile has save configuration as-script as the last command. |
xos0067079 | ACL installation for the policy authenticated client is failing when diffserv replacement and meter configuration is present in the switch. |
xos0067325 | After recovering from multiple link failures, ERPS incorrectly keeps both the ring links in blocked state. |
xos0067335 | Memory leak occurs in VMT process when it is enabled on the port. |
xos0067506 | A few VRRP instances remain in dual master state if VRRP state changes for several VLANs in the same VRID within a short time period. |
xos0067887 | Switch reboots unexpectedly when there are continuous SSH attempts and those attempts are rejected with access-profile. |
xos0067912 | The command show port protocol filter displays the "Error: Configuration reply is too big" in output. |
xos0068209 | PIM process ends unexpectedly with signal 11. |
xos0049630 | Configuring DNS server in user VR gets added to VR-default. |
xos0065527 | Edge safeguard configuration gets lost when ports are removed and added back to default VLAN. |
xos0067583 | Add support to configure ping success for VRRP track-ping. |
xos0067973 | After run failover, IDM kerberos system ACLAs are missing for some users in new master. |
xos0062668 | MIB compilation issues occur with VLAN MIB when using mgsoft. |
xos0065354 | Kernel error "packet number to save out of range: 49" occurs when DOS protect is enabled in the switch. |
xos0065930 | ACLCBFUNC log occurs after associating a policy that has CLEAR-flow and network-zone configuration. |
xos0066921 | ARP fails to resolve for some hosts. |
xos0066986 | OSPF E1 routes in NSSA area are removed or not updated properly in the routing table. |
xos0067084 | FDB is not learned over pseudowire after disabling, and then enabling, learning on network VLAN ports. |
xos0068099 | After rebooting the switch, BGP neighbor configuration is lost when a peer group is configured. |
xos0066697 | Delay occurs in password prompt appearing when trying to establish SSH connection. |
xos0067106 | In dot1x authorization, service unavailable vlan port is re-authenticated in every authorization causing blocked port. |
xos0066963 | Jumbo frame is disabled on master port after rebooting when ports are partitioned. |
xos0060343 | On Summit X670v stack, configuration file replication on standby nodes times out after second or third failover. |
xos0067446 | "ACL filter update failed" error occurs when modifying the code point value. |
xos0065571 | Ping fails over L3VPN tunnel when the corresponding ARPs are in Layer 3 hardware hash table as "Extended View". Affects Summit X450-G2, X670-G2, and X770 series switches. |
Summit X430 Series Switches | |
xos0067014 | On X430 series switches, Netlogin web-based authentication is not working. |
BlackDiamond 8800 Series Switches | |
xos0064870 | BlackDiamond 8800 series switches slots fail sometimes when applying PVLAN and STP configuration. |
BlackDiamond X8 Series Switches | |
xos0067283 | In BlackDiamond X8 series switches, the link remains in ready state after rebooting with SP7051-EXT 10Gb-T RJ45 transceiver. |
NWI Series Switches | |
xos0067397 |
Kernel error message appears when configuring dot1p examination
inner-tag:
<Erro:Kern.Error> inner dot1p filter failed in Create unit 0, rv -6 |
Summit X670G2 Series Switches | |
xos0066844 | Port with copper SFP inserted appears as active even if it is administratively disabled. |
SummitStack | |
xos0067096 | Multicast traffic is dropped on front panel port 1:1 when management port goes down on stacking switch. |
xos0058499 | In SummiStack, the snmpEngine values are maintained in each node separately instead of a single value, which is causing different values on each failover. |