The following issues were resolved in ExtremeXOS 16.2.5-Patch1-17. ExtremeXOS 16.2.5-Patch1-17 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, ExtremeXOS 16.2.3, ExtremeXOS 16.2.4, and ExtremeXOS 16.2.5. For information about those fixes, see the release notes for the specific release.
CR Number | Description |
---|---|
General | |
xos0075483 | The process cfgmgr ends unexpectedly when executing another save command after a failing first save command. |
xos0061497 | With L3VPN Dual homing, traffic is slow-path forwarded when the L3VPN peer is changed. |
xos0068278 | IP security snooping is not working for clients in sub-VLAN. Violation is detected correctly, but the corresponding action is not triggered. |
xos0076042 | The command show iproute origin static shows only eight entries after reboot. |
xos0076121 | On Summit X670V switches, temperature threshold for warnings and alarms are misleading. |
xos0076359 | With MPLS next-hop enabled, BGP control packets do not set Dot1p values. When MPLS exp examination/replacement is enabled, the packets do not have the proper exp bits set. |
xos0073012 | On BlackDiamond 8900-G48X-xl modules, 100FX optics with Phy do not come up. |