Resolved Issues in ExtremeXOS 16.2.3-Patch1-6

The following issues were resolved in ExtremeXOS 16.2.3-Patch1-6. ExtremeXOS 16.2.3-Patch1-6 includes all fixes up to and including ExtremeXOS 11.6.5.3, and earlier, ExtremeXOS 12.0.5, ExtremeXOS 12.1.7, ExtremeXOS 12.2.2-patch1-12, ExtremeXOS 12.3.6, ExtremeXOS 12.4.5, ExtremeXOS 12.5.5, ExtremeXOS 12.6.3, ExtremeXOS 12.6.5, ExtremeXOS 12.7.1, ExtremeXOS 15.1.5, ExtremeXOS 15.2.4, ExtremeXOS 15.3.3, ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2, ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 16.2, ExtremeXOS 16.2.2, and ExtremeXOS 16.2.3. For information about those fixes, see the release notes for the specific release.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in ExtremeXOS 16.2.3-Patch1-6
CR Number Description
General
xos0062013 SNMP table extremePortUtilizationExtnTable displays inaccurate value.
xos0065400 VLAN name and tag do not appear correctly when VLAN is created with VLAN name as "tag".
xos0066741 Exsh process ends unexpectedly with signal 6 when downloading the configuration using Zero Touch Provisioning (ZTP) with the DHCP option provided by DHCP server.
xos0066923 Need commands to configure "reload-delay" timer for MLAG ports.
xos0066984 RADIUS-accounting request packet shows incorrect account-terminate reason for user logout from SSH session.
xos0067063 Rtlookup is not able to display all the ECMP routes.
xos0067108 Packets received on STP-blocked ports get forwarded to other STP ports when NetLogin and ONEPolicy are enabled with authentication mode optional.
xos0067182 Authentication on switch using RSA keys stops working if one of the user keys is deleted.
xos0067227 IDMgr entries are not flushed when ARP fast-convergence is on.
xos0067323 FDBs are learned on incorrect VPLS peer on PE switches after include/exclude dot1q tag in P switch.
xos0067739 UDP configuration is lost after reboot with IP DAD enabled.
xos0067822 Memory leak occurs in XMLD process whenever Chalet session refresh happens.
xos0068356 Informational messages appear on the console when an NTP-enabled VLAN becomes inactive.
xos0068191 Nettools process ends unexpectedly with signal 11 while rebooting the switch with 100+ DHCP clients connected via Relay and with Smart Relay enabled.
xos0066483 The encrypted shared secret for TACAS accounting secondary servers does not appear in the configuration.
xos0067206 Unable to login to Chalet with any account that uses an ampersand (&) character.
xos0068023 Hash collision warning message appears with invalid VRID when exceeding hash table limit.
xos0066366 On VPLS network with LAG on access side, clearing FDB on LSRs and LERs results in traffic drop.
xos0067271 FDB mismatch occurs between software and hardware after deleting, and then adding, ISC port multiple times.
xos0064790 Number of used "L4 Port Ranges" count is incorrect in show access-list usage acl-range port output after unconfiguring few ACL rules with "L4 port range" match condition.
xos0068374 With OSPFv3 16-way ECMP, rtlookup for destination shows multiple duplicate entries.
xos0063669

Erro:RtMgr.Client.ReplyTimeOut messages appear after run failover/reboot:

<Warn:EPM.hello_rate> Slot-2: Received hellos from process rtmgr 2 more often then expected 3
<Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (ADDUPDRTE).
<Erro:RtMgr.Client.ReplyTimeOut> Slot-2: Client with ID=0x00000012 Timed out waiting for (RTEGET).
xos0066179 In Summit X440-24t and E4G-200 series switches, show fan output displays fan state as "Failed" when RPM is 0.
xos0067087 CFM LMR/DMR packets are sent with dot1p value 0.
xos0068244 Error message "Function Pointer Database is not fully initialized" appears during switch bootup with default configuration.
xos0066782 BFD session ends when removing CVID from a service VMAN port.
xos0067704 The process exsh ends unexpectedly after issuing command with include option that uses # via SSH script.
xos0068828 FDB is not learned when ONEPolicy is enabled on the port with authentication mode optional, and the client fails the authentication.
BlackDiamond 8800 Series Switches
xos0067807 On BlackDiamond 8800 series switches, the VRRP process monopolizes 40–50% CPU after disable/enable slot, or after restart ports all when the switch has VRRP enabled on 120 STP-protected VLANs.
xos0065937 Support for dual hash needs to be enabled for BlackDiamond 8800 c-series modules.
Summit X670-48t Switches
xos0067652 After a link-flap, combo ports on Summit X670V-48t switches do not link up sometimes using fiber connection.