ExtremeSwitching SLX 9250 Technical Specifications

System specifications

The ExtremeSwitching SLX 9250 Series includes the following switch models:

Part number Description

SLX9250-32C

SLX9250-32C Switch with two empty power supply slots, and six empty fan slots. Supports 32x100/40GE

SLX9250-32C-AC-F

SLX9250-32C Switch AC with Front to Back Airflow. Supports 32x100/40GE with dual power supplies, six fans

SLX9250-32C-AC-R

SLX9250-32C Switch AC with Back to Front Airflow. Supports 32x100/40GE with dual power supplies, six fans

SLX 9250 Software Specifications

Table 1. SLX 9250 Software Specifications
Software Specifications Description

Connector options

  • 40 GbE QSFP+
  • 100 GbE QSFP28
  • Out-of-band Ethernet management: 10/100/1000 Mbps RJ-45
  • Console management: RJ45 serial port and USB type-C port with serial communication device class support
  • Storage: USB port, standard-A plug
  • Sound Pressure

Maximum MAC addresses

70,000

Maximum VLANs

4,096

Maximum ACLs (IPv4/IPv6/L2)

2,000

Maximum members in a standard LAG

64

Maximum number of MCT switches

2

Maximum number of Bridge Domains

4096

Maximum IPv4 unicast routes

128,000

Maximum IPv6 unicast routes

10,000

Maximum IPv4 host routes

47,000

Maximum IPv6 host routes

33,000

Maximum jumbo frame size

9,126 bytes

QoS priority queues (per port)

8

IEEE Compliance

  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1s Multiple Spanning Tree
  • IEEE 802.1w Rapid Reconfiguration of Spanning Tree Protocol
  • IEEE 802.3 Ethernet
  • IEEE 802.3ad Link Aggregation with LACP
  • IEEE 802.3ab 1000BASE-T
  • IEEE 802.3z 1000BASE-X
  • IEEE 802.3ba / 80 2.3bm 40 GBASE-X and 100 GBASE-X
  • IEEE 802.1Q VLAN Tagging
  • IEEE 802.1p Class of Service Prioritization and Tagging
  • IEEE 802.1v VLAN Classification by Protocol and Port
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
  • IEEE 802.3x Flow Control (Pause Frames)
  • IEEE 802.3ae 10 GBASE-X
  • IEEE 802.3 10 GBASE-T (up to 100 m using Cat6a cabling or better)

Weights and Physical Dimensions

Table 2. SLX 9250 Switch Unpackaged Dimensions
SLX9250-32C (SLX 9250-32C base) Height: 4.34 cm (1.71 in)

Width: 43.96 cm (17.31 in)

Length: 53.95 cm (21.24 in)

XN-FAN-001-F: Fan unit, front-to-back or XN-FAN-001-R: Fan Unit back-to-front

Height: 4.0 cm (1.57 in)

Width: 4.0 cm (1.57 in)

Length: 13.4 cm (5.28 in)

XN-4P-RKMT298 - Four-post rack mount kit (included with switch)

Height: 2.1 cm (0.83 in)

Width: 4.4 cm (17.3 in)

Length: 63.0 cm - 90.0 cm (24.80 in - 35.43 in)

XN-2P-RKMT299 - Two-post rack mount kit (separately orderable)

Height: 4.2 cm (1.65 in)

Width: 2.4 cm (0.93 in)

Length: 12.5 cm (4.92 in)

Table 3. SLX 9250 Switch Unpackaged Weight
SLX9250-32C (SLX 9250-32C base)

7.39 kg (16.29 lb)

SLX9250-32C switch with two AC PSUs (-F and -R models)

9.8 kg (21.56 lb)

Fan unit, front-to-back or back-to-front

0.14 kg (0.31 lb)

Four-post rack mount kit (included with switch)

2.65 kg (5.84 lb)

Two-post rack mount kit (separately orderable)

0.45 kg (0.99 lb)

Table 4. SLX 9250 Switch Packaged Dimensions
SLX9250-32C Switch Height: 18.5 cm (7.28 in)

Width: 60.0 cm (23.62 in)

Length: 88.0 cm (34.65 in)

Fan unit, front-to-back or back-to-front

Height: 24.0 cm (9.45 in)

Width: 20.6 cm (8.11 in)

Length: 22.1 cm (8.70 in)

Four-post rack mount kit (included with switch)

Height: 7.0 cm (2.76 in)

Width: 11.0 cm (4.33 in)

Length: 84.0 cm (33.07 in)

Two-post rack mount kit (separately orderable)

Height: 24.0 cm (9.45 in)

Width: 20.6 cm (8.11 in)

Length: 22.1 cm (8.70 in)

Table 5. SLX 9250-32 Switch Packaged Weight
SLX9250-32C switch with no PSUs

14.59 kg (32.17 lb)

SLX9250-32C switch with two AC PSUs (-F and -R models)

17 kg (37.40 lb)

Fan unit, front-to-back or back-to-front

1.82 kg (4.01 lb)

Four-post rack mount kit (included with switch)

2.71 kg (5.97 lb)

Two-post rack mount kit (separately orderable)

3.20 kg (7.05 lb)

Acoustic Specifications

Table 6. Acoustic Specifications
Switch Model Bystander Sound Pressure (at 27°C) Declared Sound Power (at 27°C)

SLX9250-32C-AC-F (SLX 9250-32C with front-to-back airflow

45 dB(A)

6.8 bels

SLX9250-32C-AC-R (SLX 9250-32C with back-to-front airflow)

47 dB(A)

6.7 bels

Fan Tray and Speed Variation

Fan speeds are adjusted based on calculations of the temperatures on all sensors. Due to one fan being located behind the other, air pushed from one fan may cause the other fan in the module to run at a higher speed. One fan can run at medium speed while the other can spin at high speed if one is close to the temperature boundary.

Table 7. Fan Tray and Speed Variation
Description Operation Status Operation Speed Airflow Direction
Tray 1 Fan 1 up high speed Unknown*
Tray 1 Fan 2 up medium speed Unknown*
Tray 2 Fan 1 up high speed Unknown*
Tray 2 Fan 2 up medium speed Unknown*
Tray 3 Fan 1 up high speed Unknown*
Tray 3 Fan 2 up medium speed Unknown*
Tray 4 Fan 1 up high speed Unknown*
Tray 4 Fan 2 up medium speed Unknown*
Tray 5 Fan 1 up high speed Unknown*
Tray 5 Fan 2 up medium speed Unknown*
Tray 6 Fan 1 up high speed Unknown*
Tray 6 Fan 2 up medium speed Unknown*

* - The color of the tab on the fan tray indicates the airflow direction:

Power Options

Table 8. SLX 9250 Switch Power Options
SLX 9250 Switch 750 W AC power supply:

Part # XN-ACPWR-750W-F (front-to-back)

Part # XN-ACPWR-750W-R (back-to-front)

AC Input: 100-120/200-240 VAC, 50/60 Hz

3.5/1.8 A max. for each PSU

PSU Input Socket: IEC 320 C14

Power cord input plug: IEC 320 C13

750 W DC power supply:

Part # XN-DCPWR-750W-F (front-to-back)

Part # XN-DCPWR-750W-R (back-to-front)

DC Input: -48 to - 60 VDC, 7.5 A max. for each PSU

Power Consumption

Table 9. SLX 9250 Switch Power Consumption
Operating Mode Test Conditions Power Consumption
Fan Duty Traffic Load Port Status Packet Length (Bytes) Dual Power: PSU1 Dual Power: PSU2 Single Power: PSU1

Empty mode

85%

NA

Down

NA

152.6 W

145.5 W

285.9 W

Standby mode

85%

NA

Up

NA

157.6 W

151.5 W

297.2 W

Typical mode

85%

70%

Up

1,518

165 W

159.8 W

313.6 W

Stress mode

100%

100%

Up

256

207.8 W

204.5 W

406.o W

Power and Heat Dissipation

Table 10. SLX 9150 Power and Heat Dissipation
Switch Model Minimum Heat Dissipation (BTU/hr) (Idle, no ports linked) Minimum Power Consumption (Watts) (Idle, no ports linked) Maximum Heat Dissipation (BTU/hr) (Fans high, all ports 100% traffic) Maximum Power Consumption (Watts) (Fans high, all ports 100% traffic)

SLX9250-32C-AC-F

734 BTU/ hr

215W

1573 BTU/ hr

461W

SLX9250-32C-AC-R

734 BTU/ hr

215W

1573 BTU/ hr

461W

Mean Time Between Failures (MTBF)

Table 11. SLX 9250 Mean Time Between Failures (MTBF)
Switch Model Mean Time Between Failures
SLX9250-32C-AC-F ( 384936 hrs @ 25°C
SLX9250-32C-AC-R 444822 hrs @ 25°C

CPU, Memory

Table 12. CPU, Memory
1GHz 64-bit CPU
16 Gb memory, 128 Gb SSD
4GB eMMC Flash Memory
24 MB buffer for ASIC, per chip

Standards

Table 13. Safety Standards

North American Safety of ITE

UL 62368-1 2nd Ed., 2014-12-01, Listed Device (US)

UL 60950-1 2nd Ed., 2014-10-14, Listed Device (US)

CAN/CSA 22.2 #62368-1-14 2nd Ed., Canada

CAN/CSA 22.2 #60950-1-07 2nd Ed., Canada 2014-10

Complies with FCC 21 CFR Chapter 1, Sub-chapter J in accordance with FDA & CDRH requirements (US Laser Safety)

CDRH Letter of Approval (US FDA Approval)

European Safety of ITE

EN 62368-1:2014/A11:2017

EN 60950-1:2006 + A11:2009 + A12:2010 + A2:2013

2014/35/EU Low Voltage Directive

International Safety of ITE

CNS 14336-1

AS/NZX 60950-1 (Australia /New Zealand)

GB4943.1-2001

IEC/EN 60825-1:2007, IEC/EN 60825-2:2004+A1+A2 or later (Lasers Safety)

IEC 62368-1:2014 (2ndEd.)

IEC 60950-1:2005 (2nd Ed.) + Am 1:2009 + Am 2:2013 + National Difference

Table 14. EMI/EMC Standards

North America EMC for ITE

  • FCC 47 CFR part 15 subpart B Class A (USA)
  • ICES-003 (Canada)

European EMC standards

  • EN 300 386 V2.1.1(2016-07) Class A
  • EN 55032:2015/AC:2016-07 Class A
  • EN 55024:2010/A1:2015
  • EN 55011:2009+A1:2010 (Group 1, Class A)
  • EN 61000-6-2:2005+AC:2005
  • EN 61000-6-4:2007+A1:2011
  • EN 61000-3-2:2014 Class A
  • EN 61000-3-3:2013
  • EN 61000-4-2:2009
  • EN 61000-4-3:2006+A1:2008+A2:2010
  • EN 61000-4-4:2012
  • EN 61000-4-5:2014
  • EN 61000-4-6:2014/AC:2015
  • EN 61000-4-8:2010
  • EN 61000-4-11:2004/A1:2017

International EMC certifications

  • IEC 61000-6-2:2016 ED 3.0
  • IEC 61000-6-4:2018 ED 3.0
  • IEC 61000-4-2:2008 ED 2.0
  • IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 ED 3.2
  • IEC 61000-4-4:2012 ED 3.0
  • IEC 61000-4-5:2014+AMD1:2017+ ED 3.1
  • IEC 61000-4-6:2013+ ED 4.0
  • IEC 61000-4-8:2009+ ED 2.0
  • IEC 61000-4-11:2004+AMD1:2017+ ED 2.1
  • CISPER 32:2015 ED 2.0 Class A
  • CISPER 24:2010+AMD1:2015 Class A
  • CISPER 11:2009 ED 5.0 Group 1, Class A
  • AS/NZS CISPER 32:2015 Class A
  • GB/T9254-2008 Class A
  • ANSI C63.4:2014

Country-specific

  • RCM (Australia)
  • VCCI Class A (Japan)
  • MSIP KCC (Korea)
  • BSMI (Taiwan)
  • ANATEL (Brazil)
  • CCC mark (China)
  • SABS & NRCS (South Africa)
  • UL, FCC (North America)
  • EAC mark (Custom Union)
Table 15. Telecom Standards

EN/ETSI 300 386:2008 (EMC Telecommunications)

EN/ETSI 300 019 (Environmental for Telecommunications)

MEF9 and MEF14 certified for EPL, EVPL, and ELAN

Table 16. IEEE 802.3 Media Access Standards

IEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-X

IEEE 802.3ae 10GBASE-X

IEEE 802.3ba 40GBASE-X

Environmental Data

Table 17. Environmental Data

Environmental standards

EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage

EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation

EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational

EN/ETSI 300 753 (1997-10) - Acoustic Noise

ASTM D3580 Random Vibration Unpackaged 1.5G

Temperature range

  • Front-to-back airflow: 0°C to 50°C (32°F to 122°F) up to 1800m (6000 ft)
  • Front-to-back airflow: 0°C to 45°C (32°F to 113°F) above 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 45°C (32°F to 113°F) up to 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 40°C (32°F to 104°F) above 1800m (6000 ft)

Other operating conditions

Humidity: 5% to 95% relative humidity, non-condensing

Altitude: 0 to 3,000 meters (9,850 feet)

Operational shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks

Operational random vibration: 3 to 500 Hz at 1.5 G rms

Storage & transportation conditions (packaged)

Transportation temperature: -40°C to 70°C (-40°F to 158°F)

Humidity: 5% to 95% relative humidity, non-condensing

Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks

Packaged sine vibration: 5 to 62 Hz at velocity 5 mm/s,

62 to 500 Hz at 0.2 G

Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct.

from 20 to 200 Hz

14 drops minimum on sides and corners at 42 in (<15 kg box)