Learn how to connect the ETH1 or
ETH0 cable through the large conduit hole on the metal sloping bracket.
About this task
The following hardware is required to attach the ETH1 or ETH0 cable through the large
conduit hole on the metal sloping bracket:
- ETH1 or ETH0 cable
- Two blank conduit covers to cover the front and the rear holes on the side
of the service panel base
- One metal sloping bracket
Note
The conduit cover used on the metal sloping bracket can extend above the
concrete floor but, cannot extend above the slope.
Callout |
Description |
1 |
Large conduit hole on the metal sloping bracket |
Procedure
-
Attach the metal sloping bracket
to the concrete floor using two anchors, nuts, and washers.
-
Attach the conduit to the metal
sloping bracket.
-
Bring in the ETH1 or ETH0 cable
through the conduit hole.
-
Remove the gland cap, plastic
cage, and the gasket from the ETH1 port.
Note
Put the
removed parts onto the LAN cable to be attached to the access point
later.
-
Connect the ETH0 LAN cable
through the ETH0 port until it clicks into place.
If there is a ETH1 connection,
insert the cable through the ETH1 gland until it locks into place into the ETH1
port.
-
Torque the gland cap to 12-in
lbs.
-
Fold and arrange the ETH0 cable
into the gap of the metal sloping bracket and the service panel base.