Connect the ETH1 or ETH0 Cable through the Metal Sloping Bracket

Learn how to connect the ETH1 or ETH0 cable through the large conduit hole on the metal sloping bracket.

About this task

The following hardware is required to attach the ETH1 or ETH0 cable through the large conduit hole on the metal sloping bracket:
  • ETH1 or ETH0 cable
  • Two blank conduit covers to cover the front and the rear holes on the side of the service panel base
  • One metal sloping bracket
Note

Note

The conduit cover used on the metal sloping bracket can extend above the concrete floor but, cannot extend above the slope.
Click to expand in new window
Metal sloping bracket with large conduit hole
Metal sloping bracket highlighting the conduit hole on the left side for conduit connection
Callout Description
1 Large conduit hole on the metal sloping bracket

Procedure

  1. Attach the metal sloping bracket to the concrete floor using two anchors, nuts, and washers.
  2. Attach the conduit to the metal sloping bracket.
  3. Bring in the ETH1 or ETH0 cable through the conduit hole.
  4. Remove the gland cap, plastic cage, and the gasket from the ETH1 port.
    Note

    Note

    Put the removed parts onto the LAN cable to be attached to the access point later.
  5. Connect the ETH0 LAN cable through the ETH0 port until it clicks into place.
    If there is a ETH1 connection, insert the cable through the ETH1 gland until it locks into place into the ETH1 port.
  6. Torque the gland cap to 12-in lbs.
  7. Fold and arrange the ETH0 cable into the gap of the metal sloping bracket and the service panel base.