View topology message status to view the interconnections between Layer 2 devices in a network.
show autotopology nmm-table
None
User EXEC
The show autotopology nmm-table command displays the following information:
| 
                         Output field  | 
                     
                         Description  | 
                  
|---|---|
| 
                         Local Port  | 
                     
                         Specifies the slot and port that received the topology message.  | 
                  
| 
                         IpAddress  | 
                     
                         Specifies the IP address of the sender of the topology message.  | 
                  
| 
                         SegmentId  | 
                     
                         Specifies the segment identifier of the segment from which the remote agent sent the topology message. This value is extracted from the message.  | 
                  
| 
                         MacAddress  | 
                     
                         Specifies the MAC address of the sender of the topology message.  | 
                  
| 
                         ChassisType  | 
                     
                         Specifies the chassis type of the device that sent the topology message.  | 
                  
| 
                         BT  | 
                     
                         Specifies the backplane type of the device that sent the topology message. The switch uses a backplane type of 12.  | 
                  
| 
                         LS  | 
                     
                         Indicates if the sender of the topology message is on the same Ethernet segment as the reporting agent.  | 
                  
| 
                         CS  | 
                     
                         Specifies the current state of the sender of the topology message. The choices are 
  | 
                  
| 
                         Rem Port  | 
                     
                         Specifies the slot and port that sent the topology message.  | 
                  
The following example displays the topology message status.
Switch:1(config)#show autotopology nmm-table 
==========================================================================================
                                      Topology Table 
==========================================================================================
Local                                                                              Rem  
Port     IpAddress       SegmentId MacAddress   ChassisType            BT LS  CS   Port 
------------------------------------------------------------------------------------------
0/0      192.0.2.81     0x000000  0030ab707a00 ChassisType 1          12 Yes HtBt  0/0 
1/1      192.0.2.81     0x000000  0050ea268800 ChassisType 2          12 Yes HtBt  1/50 
1/42     192.0.2.81     0x000000  070ab307aa00 ChassisType 3          12 Yes HtBt  1/1 
2/1      192.0.2.81     0x000000  0030ab57ab00 ChassisType 4          12 Yes HtBt  1/49 
2/2      192.0.2.81     0x000000  0030ab307af0 ChassisType 5          12 Yes HtBt  1/50 
2/41     192.0.2.81     0x000000  00e0ba327c00 ChassisType 6          12 Yes HtBt  2/1 
2/42/1   192.0.2.81     0x000000  0050eb127400 ChassisType 7          12 Yes HtBt  1/2