Display isis spbm related info.
show isis spbm
None
User EXEC
The show isis spbm command displays the following information:
| 
                         Output field  | 
                     
                         Description  | 
                  
|---|---|
| 
                         SPBM INSTANCE  | 
                     
                         Indicates the SPBM instance identifier. You can only create one SPBM instance.  | 
                  
| 
                         B-VID  | 
                     
                         Indicates the SPBM B-VLAN associated with the SPBM instance.  | 
                  
| 
                         PRIMARY VLAN  | 
                     
                         Indicates the primary SPBM B-VLAN.  | 
                  
| 
                         NICK NAME  | 
                     
                         Indicates the SPBM node nickname. The nickname is used to calculate the I-SID multicast MAC address.  | 
                  
| 
                         LSDB TRAP  | 
                     
                         Indicates the status of the IS-IS SPBM LSDB update trap on this SPBM instance. The default is disable.  | 
                  
| 
                         IP  | 
                     
                         Indicates the status of SPBM IP shortcuts on this SPBM instance. The default is disable.  | 
                  
| 
                         IPv6  | 
                     
                         Indicates the status of SPBM IPv6 shortcuts on this SPBM instance. The default is disable.  | 
                  
| 
                         MULTICAST  | 
                     
                         Indicates if SPBM multicast is enabled. The default is disabled.  | 
                  
| 
                         SPB-PIM-GW  | 
                     
                         Indicates if SPB PIM Gateway is enabled. The default is disabled.  | 
                  
| 
                         STP-MULTI HOMING  | 
                     
                         Indicates if MSTP-Fabric Connect Multi Homing is enabled. The default is disabled.  | 
                  
| 
                         SMLT-SPLIT-BEB  | 
                     
                         Specifies whether the switch is the primary or secondary vIST peer.  | 
                  
| 
                         SMLT-VIRTUAL-BMAC  | 
                     
                         Specifies a virtual MAC address that can be used by both peers.  | 
                  
| 
                         SMLT-PEER-SYSTEM-ID  | 
                     
                         Specifies the vIST peer system ID.  |