The following example enables loop detection on a VLAN and enters Protocol Loop Detection configuration mode.
device# configure terminal device(config)# vlan 5 device(config-vlan-5)# loop-detection device(config-loop-detect)#
The following example enables ports associated with VLAN 8 and clears LD statistics for that VLAN.
device# clear loop-detection vlan 8
The following example displays LD configuration values, including logical interfaces (LIFs), for a VLAN tunnel.
device# show loop-detection vlan 20 Number of LD instances: 1 LIF (Logical Interface) Disabled on Ports: eth2/2 Packet Statistics: vlan sent rcvd 20 119 1
The following example displays LD configuration values for a VLAN tunnel if LD shutdown is disabled.
device# show loop-detection vlan 20 Number of LD instances: 1 LIF (Logical Interface) ShutDown is disabled for VLAN 20 Packet Statistics: vlan sent rcvd 20 10 10
The following example disables the shutdown of a VLAN VLAN tunnel.
device# configure terminal device(config)# vlan 20 device(config-vlan-20)# loop-detection-shutdown-disable
You can control the auto-enable behavior of an LD-disabled logical interface (LIF), by using the shutdown-time command in Protocol Loopback Detection configuration mode. The following example specifies a shutdown time of 1 minute.
device# configure terminal device(config)# loop-detection device(config-loop-detect)# shutdown-time 1 2017/10/20-16:04:48, [ELD-1005], 3749, M2 | Active | DCE, INFO, SLX, Loop is detected on Ethernet 2/2 VLAN 20, the LIF (logical interface) is shutdown. 2017/10/20-16:05:46, [ELD-1007], 3750, M2 | Active | DCE, INFO, SLX, Loop detection disabled LIF (Logical interface) on Ethernet 2/2 VLAN 20 is auto-enabled.
By default the shutdown time is 0, which means that an LD-disabled LIF is never auto-enabled. If the shutdown time is configured with a nonzero value, the LD-disabled LIF is auto-enabled following the specified shutdown time.
To enable LD-disabled ports and clear LD statistics on all interfaces, use the clear loop-detection command as in the following example.
device# clear loop-detection