Message: Linux socket error - error reason: <reason>, socket name: <sockname>, error name <errorname>.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that an error has occurred in the Linux socket.
Recommended Action: Reload or power cycle the switch.
Message: Initialization error: <reason>.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that the Layer 2 system (L2SYS) has encountered an error during initialization.
Recommended Action: Reload or power cycle the switch.
Message: Message Queue Error: Failed to create a Message Queue.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that the Layer 2 system (L2SYS) has encountered system service manager (SSM) message queue errors.
Recommended Action: Reload or power cycle the switch.
Message: FDB error: Error in creating the AVL tree.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that the Layer 2 system (L2SYS) has encountered an error while initializing the AVL tree.
Recommended Action: Reload or power cycle the switch.
Message: MAC-address-table hash failed even after two attempts for slot <slot> chip <chip>.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that the media access control (MAC) address table hash failed even after two hash changes on the specified chip.
Recommended Action: Reload or power cycle the switch.
Message: MAC-address-table is 95 percent full.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the media access control (MAC) address table on the chip is 95 percent full.
Recommended Action:Clear some of the entries using the clear mac-address-table dynamic command or wait until the old entries age out.
Message: MAC-address-table on slot <Slot_id> chip <Chip_id> is less than 90 percent full.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the media access control (MAC) address table on the specified chip is less than 90 percent full.
Recommended Action:No action is required. The Layer 2 system (L2SYS) will start learning the entries
Message: Adding Internal MAC <mac1>:<mac2>:<mac3>:<mac4>:<mac5>:<mac6> VID <Vid> as a static MAC.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that a static media access control (MAC) is overriding an internal MAC entry (VRRP/SVI).
Recommended Action: No action is required.
Message: Fabric-wide Layer 2 flush command issued.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that a fabric-wide Layer 2 flush command is issued and the entire Layer 2 forwarding table will be cleared.
Recommended Action: No action is required.
Message: Fabric-wide l2 flush completed, status - <command status>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the entire Layer 2 forwarding table has been cleared.
Recommended Action: No action is required.
Message: Security violation occured on interface <Ifname> with Mac <mac1><mac2>.<mac3><mac4>.<mac5><mac6> Vlan <vid>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the number of Media Access Control (MAC) addresses allowed on the specified interface has reached the maximum limit. Based on the configured action, the interface is either shut down or the MAC learning is restricted.
Recommended Action: No action is required.
Message: Failed to create Tunnel <Ifid>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel creation was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to delete Tunnel <Ifid>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel deletion was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to handle Tunnel-Vlan association, Tunnel <Ifid> not found.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel VLAN association handling was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to handle Tunnel-Vlan disassociation, Tunnel <Ifid> not found.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel VLAN disassociation handling was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to associate Tunnel <Ifid> to Vlan <Vid>, Vlan not present.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel VLAN association was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to disassociate Tunnel <Ifid> from Vlan <Vid>, Vlan not present.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that tunnel VLAN disassociation was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to configure Remote VM MAC <mac1><mac2>.<mac3><mac4>.<mac5><mac6> for Tunnel <ifid> on Vlan <vid>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that configuring remote Virtual Machine (VM) Media Access Control (MAC) on the tunnel was unsuccessful.
Recommended Action: Technical support is required.
Message: Failed to remove Remote VM MAC <mac1><mac2>.<mac3><mac4>.<mac5><mac6> for Tunnel <ifid> on Vlan <vid>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that removing remote Virtual Machine (VM) Media Access Control (MAC) on the tunnel was unsuccessful.
Recommended Action: Technical support is required.
Message: MAC move detected across interface(s) <InterfaceList> for MAC <mac1>:<mac2>:<mac3>:<mac4>:<mac5>:<mac6>, VLAN <Vlan ID>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the MAC address is flapping across multiple interfaces.
Recommended Action: No action is required.
Message: Rate limiting frequent MAC move detection logs. No more logs will be reported.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that MAC move logging has been stopped to avoid flooding.
Recommended Action: Use "mac-move-detect log reset-count" to know if MAC moves are still happening
Message: MAC move detection and Virtual fabric can not co-exist. Disabling MAC move.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that Virtual fabric was enabled after enabling MAC move detection.
Recommended Action: Disable Virtual fabric to enable MAC move detection again.
Message: Repeated mac move detected for Mac <mac1><mac2>.<mac3><mac4>.<mac5><mac6> Vlan <vid>, interface <Ifname> shut down.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates port shut down due to repeated mac move.
Recommended Action: No action is required.
Message: Shut down recovery for interface <interface>
Message Type: DCE
Severity: INFO
Probable Cause: Indicates port shut recover due to multiple ports getting shut.
Recommended Action: No action is required.
Message: Loop Detection (ELD) has triggered mac-address-table refresh
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that Edge Loop Detection (ELD) has detected loop and triggered mac-address-table refresh.
Recommended Action: No action is required.
Message: Edge Loop Detection (ELD) has triggered mac-address-table refresh for interface <interface>
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that Edge Loop Detection (ELD) has detected loop and triggered mac-address-table refresh for specified interface.
Recommended Action: No action is required.
Message: Duplicate MCT Static MAC addresses are identified.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that Between MCT Nodes duplicate static macs found .
Recommended Action:Delete the Duplicate MAC one of the MCT Node.
Message: Duplicate static VPLS Mac <mac1>02x<mac2>02x.<mac3>02x<mac4>02x.<mac5>02x<mac6>02x is detected in bridge-domain <vid> on logical-interface <Ifname>.
Message Type: DCE
Severity: ERROR
Probable Cause: Indicates that duplicate vpls static mac is configured in bridge-domain.
Recommended Action: Delete the latest Duplicate static MAC configured.
Message: MAC-address-table has reached user configured high threshold limit.
Message Type: DCE
Severity: INFO
Probable Cause: MAC Address Table has reached the user configured high threshold level.
Recommended Action: Clean up the MAC Address Table.
Message: MAC-address-table has dropped below user configured low threshold limit.
Message Type: DCE
Severity: INFO
Probable Cause: MAC Address Table has dropped below the user configured low threshold level.
Recommended Action: No action is required