Message: HSL initialization failed.
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates a hardware subsystem layer (HSL) initialization failure. This error is caused by other system errors.
Recommended Action: Execute the copy support command and contact your switch service provider.
Message:Failed to acquire the system MAC address pool.
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates the failure to acquire the system address. This error is caused by other system errors.
Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.
Message: Incompatible SFP transceiver for interface <InterfaceName> is detected.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been inserted.
Recommended Action: Disable the interface using the shutdown command and insert an SFP transceiver that is supported on the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown command
Message: Failed to get the kernel page size <PageSize> bytes for the Memory Map (MMap).
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates that there is not enough contiguous kernel memory.
Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.
Message: Failed to create Extreme trunk interface <InterfaceName>.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates failure to create Extreme trunk because the hardware resources are exhausted.
Recommended Action: Do not exceed the maximum trunk configuration allowed by the system.
Message: Reached max VRBIDs usage, VRB-ID allocation failed in ASIC.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that maximum VRBIDs have been used.
Recommended Action: No action is required.
Message: Resource limit reached, <Number of resources to be freed.> resources are required for the virtual-fabric entry.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that maximum resources have been used.
Recommended Action: No action is required.
Message: interface <InterfaceName> received remote fault.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates interface has received a remote fault from peer.
Recommended Action: No action is required.
Message: interface <InterfaceName> detected local fault.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates interface has detected a local fault.
Recommended Action: No action is required.
Message: Remote fault cleared on interface <InterfaceName>.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates remote fault is cleared on interface.
Recommended Action: No action is required.
Message: Local fault cleared on interface <InterfaceName>.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates local fault is cleared on interface.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not Extreme branded.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates optic is not Extreme branded.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not compatible.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates optic is not compatible with current port configuration.
Recommended Action: No action is required.
Message: FEC Resources on LC: <linecardid> unit: <unit> are exhausted. Time since last log <current_time> and total fail count: <fail_count>.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates FEC resources are exhausted on the unit of line card.
Recommended Action: No action is required.
Message: Service Port link is UP/Down
Message Type: LOG
Severity: INFO
Probable Cause: When Service Port link is Changed by up to down and vice-versa.
Recommended Action: No action is required.
Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].
Message Type: LOG
Severity: INFO
Probable Cause: Indicates status for Offline Diagnostic Test for a line card / SFM.
Recommended Action: No action is required.
Message: Offline Diagnostic Test on file no found on <lc_sfm_type>: <linecardid>.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates Offline Diagnostic Test file not present on a line card / SFM.
Recommended Action: No action is required.
Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates failure status for Offline Diagnostic Test for a line card / SFM.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not compatible and laser is disabled.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates optic is not compatible with current port configuration.
Recommended Action: No action is required.
Message: <msg>
Message Type: LOG
Severity: INFO
Probable Cause: None
Recommended Action: None.
Message: Temperature of optic inserted in interface <InterfaceName> is above critical threshold and it is put in reset.
Message Type: LOG
Severity: CRITICAL
Probable Cause:Indicate the optic temperature in the cage is over critical threshold
Recommended Action: Replace a new optic and do shut/no shut on the port.
Message: Temperature of optic inserted in interface <InterfaceName> is above warning threshold.
Message Type: LOG
Severity: WARNING
Probable Cause:Indicates that the optic temperature in the specified interface is over warning threshold.
Recommended Action: Replace a new optic and do shut/no shut on the port.
Message: fec mode <RS-FEC | FC-FEC | Auto-Negotiation | Disabled>
Message Type: LOG
Severity: ERROR
Probable Cause: This message is generated when an unsupported FEC mode is configured on an interface with 25G optics. The affected interface is identified in the message.
Recommended Action: Confirm the supported FEC modes for the optic in question with the Release Notes. Verify that the optic is configured for the appropriate FEC mode. If you attempt to configure any mode other than a supported mode for that optic, then an Error Message will be generated.
Message: {NexthopTable|RouteTable|HostTable|ECMPTable|EncapTable} reached the high threshold limit of {high-threshold-level}.
Message Type: WARNING
Severity: WARNING
Recommended Action: Reduce the size of the Next Hop Table or Route Table.
Message: {NexthopTable|RouteTable|HostTable|ECMPTable|EncapTable} reached the low threshold limit of {low-threshold-level}.
Message Type: WARNING
Severity: WARNING
Recommended Action: No action is required.