configure fabric attach zero-touch-client

configure fabric attach zero-touch-client client [vlan [[vlan_name | vlan_id] [nsi nsi | isid isid] {priority [priority | dot1p]} {bypass-netlogin[ on | off]}{enable | disable} | none] | bypass-netlogin[on | off] | enable | disable]

Description

Configures the Fabric Attach Zero Touch Client.

Syntax Description

zero-touch-client Specifies Zero Touch Client.
clientSpecifies the type of Fabric Attach client.
vlanSpecifies the VLAN on which to configure Zero Touch Clients.
vlan_nameSpecifies the VLAN name. The VLAN must be a tagged VLAN.
vlan_id Specifies the VLAN ID tag (1 and 4,094).
nsiNetwork Service Identifier.
nsiSpecifies the Network Service Identifier. Range is 1-16777215.
insiIndividual Network Service Identifier
insiSpecifies the Individual Network Service Identifier. Range is 1-16777215.
prioritySpecifies the Zero Touch port priority for untagged packets.
prioritySpecifies the priority number to be used for untagged packets. Range is 0-7.
dot1pSpecifies the use of dot1p port priority for untagged packets (default).
bypass-netloginSpecifies Netlogin authentication can be bypassed for the specified client type.
onNetlogin authentication is bypassed for the specified client type, if Netlogin is enabled on the port.
offNetlogin authentication is not bypassed for the specified client type, if Netlogin is enabled on the port (Default).
noneSpecifies no Zero Touch Client VLAN in use.
enableSpecifies enabling Zero Touch Clients.
disableSpecifies disabling Zero Touch Clients (default).

Default

Unless configured, all clients are configured to disabled state without a mapping.

Usage Guidelines

This command is only used when operating as a Fabric Attach server. It has no effect when operating as a client or proxy.

The specified VLAN configuration on the Fabric Attach server is restricted to only tagged VLANs.

Example

The following example configures the Fabric Attach Zero Touch Client "switch" with a VLAN named "V2000" and Individual Service Identifier of 2000 with a priority of 1 for untagged packets:

# configure fabric attach zero-touch-client switch vlan v2000 nsi 2000 priority 1

History

This command was first available in ExtremeXOS 31.3.

Platform Availability

This command is available on all platforms.