output-power
    (iot-device-type-imagotag-policy)
  
  
    Configures the maximum output power for
      the ESL communicator.
    Supported in the following platforms:
      
      
        - Access Points — AP-8432
 
        - Wireless Controllers — RFS 4000
 
        - Service Platforms — NX 5500, NX 75XX, NX 95XX, NX 96XX, VX 9000
 
      
     
    Syntax
      
      output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]
     
    Parameters
      
      output-power [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H]
      
          
          
          
            
              | output-power
                [Level-A|Level-B|Level-C|Level-D|Level-E|Level-F|Level-G|Level-H] | 
              Configure the ESL communicator‘s output power in dBm.
                The options are:
                  - Level-A – 1 dBm. This is the default setting.
 
                  - Level-B - -4 dBm
 
                  - Level-C - -6 dBm
 
                  - Level-D - -12 dBm
 
                  - Level-E - 0 dBm
 
                  - Level-F - -2 dBm
 
                  - Level-G - -8 dBm
 
                  - Level-H - -10 dBm
 
                 
Note: SES-Imagotags recommends NOT to change the default
                  setting, which is in conformance to various country/region specific RF
                  regulations. 
 | 
             
          
         
 | 
     
    Examples
      
      nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#output-power Level-B
      nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#show context
 iot-device-type-imagotag-policy ImagoTagPolicy
  enable
  output-power Level-B
  fcc-enable
  channel 9
nx9500-6C8809(config-iot-device-type-imagotag-policy-ImagoTagPolicy)#