Mounting the AP3965 to a Pole
To fit the mounting plate to a pole:
-
Determine the diameter of the pole.
Pole Diameter Cable Clamp Size <= 2.5” [63.5mm] Use small cable clamp 6” - 7” (178mm) Use large cable clamp Note
For other pole diameters, provide your own stainless steel cable clamp. The band must be ½” (12.7mm) wide. - Attach the AP to the “H” bracket on the side that does not have the PEM stand-offs. Tighten the four screws to a torque of 12.0 in-lbs.
- Using four M4 screw assemblies, attach the pole bracket onto the “H” bracket. Tighten the screws to 12.0 in-lbs.
-
Position the pole mount bracket onto the AP mounting bracket.
Attach Pole Bracket to “H” Bracket
-
Attach the two cable clamp to the pole bracket. Open the cable clamp by turning
a flat bladed screwdriver counterclockwise. Then, insert the non-clamp end into
the pole bracket through the holes.
Note
It is easier to install both clamps before attaching to the pole.Pole Mount Orientation - Put the metal band around the pole and insert it into the clamp.
- Turn the clamp screw clockwise, tightening the band around the pole.
-
Secure the AP to the pole by tightening the stainless steel tie back
strap.
AP3965 Pole Mount Option