Connect the ETH1 or ETH0 Cable through the Service Panel Base

The ETH1 or ETH0 cable can be connected through the front or the rear hole on the side of the service panel base

About this task

The ETH1 or ETH0 cable is connected through the side or bottom holes on the service panel base.

The following hardware is required to attach the ETH1 or ETH0 cable through a hole on the service panel base:
  • ETH1 or ETH0 cable
  • One blank conduit cover to cover the front hole on the side of the service panel base
  • One 3/4 in. or 1/2 in. conduit cover, depending on the circumference of the ETH1 or ETH0 conduit
  • Service panel base
  • Sevice panel top
  • ACC-CAT6-LAN-GSKT
  • RJ-45 Plugs
  • Four flat head long M4 screws to hold the service panel to the access point
Click to expand in new window
Metal conduit covers
Three metal conduit covers for the service panel
Callout Description
1 Blank conduit cover to cover the front hole on the side of the service panel base
2 ¾ in. conduit cover
3 ½ in. conduit cover

Procedure

  1. Using the blank conduit cover, cover the front hole of the service panel base
  2. Attach either the ½ in. conduit cover or the ¾ in. conduit cover to the rear hole of the service panel base.
  3. Bring in the ETH1 or ETH0 cable, and the ground wire through the rear side hole of the service panel base.
  4. Loosely align the service panel base next to the metal sloping bracket, thereby leaving enough space to attach the ETH1 or ETH0 cable to the access point.
  5. Attach the ground wire to the access point.
  6. Remove the gland caps, plastic cage, and the gasket from the ETH0 port.
    Note

    Note

    Put the removed parts onto the LAN cable to be attached to the access point later.
  7. Connect the ETH0 LAN cable through the ETH0 gland port until it clicks into place in the GE1 port.
    If there is a ETH1 connection, insert the cable through the ETH1 gland until it locks into place in to the GE2 port.
  8. Torque the gland cap to 12-in lbs.
  9. Fold and arrange the ETH0 cable into the gap of the metal sloping bracket and the service panel base.
    The ETH0 cable must not be bent sharply and must have 1 in. bend radius.