Create an SLX UDA Match in the Library

Matches that you create in the library can be imported as needed to one or more devices.

Before you begin

Create a UDA profile to associate with the match. For more information, see Create an SLX UDA Profile.

Procedure

  1. In the Navigation menu, select Library > Match.
  2. Select Add Match.
  3. In the Name field, enter a unique name for the match.
  4. In the Device Type field, select SLX.
  5. In the Type field, select UDA.
  6. In the UDA field, select the UDA profile to associate with the match.
  7. In the Sequence field, enter a value to represent the order in which the match performs the selected actions on the items in the profile.
  8. In the rest of the Match section, complete each field, including a mask for each item.

    The items that appear in the Match section vary by the items in the selected UDA profile.

  9. In the Action section, select one or more actions to perform on the profile items.
    • Count to keep track of the number of packets that match the policy rule
    • Drop to drop the packet
    • Log to add the transaction to the Visibility Manager log.
  10. Select Add.
    The match parameters (the new rule) appear in the pane on the right.
  11. Repeat steps 7 through 10 until you have added all the rules you need.
  12. To remove a rule from the match, select Delete for that rule in the Rules panel on the right.
  13. To change a rule, select Edit for that rule in the Rules panel and make your changes.
  14. Save () your selections.