Following is a description of the parameters and related values. Not all options are available with all radio frequencies; menu options are contextual for each of the 2.4 GHz, 5.0/4.9 GHz and 6.0 GHz frequencies.
| 
                                         Channel Width  | 
                                    
                                         Set the channel width the meshpoint‘s automatic channel scan assigns to the selected radio. Available options include: 
  | 
                                
| 
                                         Priority Meshpoint  | 
                                    
                                         Configure the meshpoint monitored for automatic channel scans. This is the meshpoint assigned priority over other available mesh points. When configured, a mesh connection is established with this mesh point. If not configured, a meshpoint is automatically selected.  | 
                                
| 
                                         Meshpoint: Path Minimum  | 
                                    
                                         Set the minimum path metric (from 100 - 20,000) for establishing mesh connections. The default setting is 1000.  | 
                                
| 
                                         Meshpoint: Path Metric Threshold  | 
                                    
                                         Configure a minimum threshold (from 800 - 65535) for triggering an automatic channel selection for meshpoint selection. The default is 1500.  | 
                                
| 
                                         Meshpoint: Tolerance Period  | 
                                    
                                         Configure the duration to wait before triggering an automatic channel selection for the next hop. The default is 1 minute.  | 
                                
| 
                                         Meshpoint Root: Sample Count  | 
                                    
                                         Set the number of scans (from 1- 10) for data collection before a mesh point root is selected. The default is 5.  | 
                                
| 
                                         Meshpoint Root: Off-channel Duration  | 
                                    
                                         Configure the duration (from 20 - 250 milliseconds) that the scan dwells on each channel when performing an off-channel scan. The default is 50 milliseconds.  | 
                                
| 
                                         Meshpoint Root: Channel Switch Delta  | 
                                    
                                         Configure the delta (from 5 - 35 dBm) that triggers a meshpoint root automatic channel selection when exceeded. The default is 10 dBm.  | 
                                
| 
                                         Meshpoint Root: Off-channel Scan Frequency  | 
                                    
                                         Configure the duration (from 1 -60 seconds) between two consecutive off channel scans for meshpoint root. The default is 6 seconds.  | 
                                
| 
                                         Meshpoint Root: Channel Hold Time  | 
                                    
                                         Set the minimum duration (from 0 - 1440 minutes) to remain on a selected channel before channel conditions are reassessed for a possible channel change. Set this value to zero (0) to prevent an automatic channel selection from occurring. The default is 30 minutes.  | 
                                
Click Reset to revert to the last saved configuration.