Shows the OpenFlow configuration state for the specified ports.
| vlan |
Specifies that show output is restricted to a specified VLAN. |
| vlan_name |
Specifies a named VLAN. |
None.
If the VLAN name is specified, the output is restricted to that VLAN.
The following example displays show output for all configured OpenFlow ports:
show openflow
OpenFlow: Enabled
Versions: OpenFlow10, OpenFlow13
Mode: Standard
FDB: Off
Access-list width: Single
Controller : Primary
Status : ACTIVE
Datapath ID : 00000004967e29a4
VR : VR-Mgmt
Mode : out-of-band Active
Target : tcp:10.68.61.216:6633
Uptime(secs) : 360827
Controller : Secondary
Not configured.
Flows
VLAN VID Mode Ports Active Error
-------------------------------- ---- -------- ----- ------ ------
turq 99 Standard 1 0 0
azure 25 Hybrid 1 0 0
Total number of VLAN(s): 2
This command was first available in ExtremeXOS 15.3.
OpenFlow version and mode information were added in ExtremeXOS 15.7.1.
This command is available on platforms that support the appropriate license. For complete information about software licensing, including how to obtain and upgrade your license and which licenses support the BGP (Border Gateway Protocol) feature, see the Feature License Requirements document.