Replacing Fans F8-F10
To replace an F8-F10 fan,
follow these steps:
-
Put on the ESD wrist strap and attach it to the ground receptacle on the front of the SSA.
-
Remove the side panel from
the SSA by unscrewing the eight zinc (silver) screws from the side panel.
-
Set the side panel upside
down to view the label on the inside of the side panel that indicates the position of
each fan.
-
Disconnect and remove fan F7
to access the F8-F10 bank of connectors, located behind fan F7.
-
Lift the failed fan out of the chassis.
-
Disconnect the failed fan from the appropriate connector.
- F8 connector: left connector
- F9 connector: middle connector
- F10 connector: right connector
-
Unwind the replacement fan‘s cables.
-
Remove the cable clip from
the replacement fan. You may discard the cable clip.
-
With the label side of the
replacement fan facing into the SSA and the cable on the left, connect the
replacement fan to the chassis connector.
-
Feed the excess fan cable
into the cable management clip.
-
Position the cables of the F8-F10 fans on the floor of the SSA.
-
Position the F8-F10 fans on top of their cables.
-
Reinstall fan F7.
-
Reinstall the side panel of the SSA.
You can now reinstall the SSA in the equipment
rack.