Display all configured service instance identifiers (I-SID) on port.
show interfaces gigabitEthernet i-sid {slot/port[/sub-port][-slot/port[/sub-port]][,...]}
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.
None
Privileged EXEC
The show interfaces gigabitEthernet i-sid command displays the following information:
Output field |
Description |
---|---|
PORTNUM |
Specifies the port number. |
IFINDEX |
Specifies a value that uniquely identifies the port. |
ISID ID |
Specifies the service interface identifier (I-SID). |
VLANID |
Specifies the backbone VLAN. |
C-VID |
Specifies the customer VLAN ID. |
ISID TYPE |
Specifies the type of I-SID. |
ORIGIN |
Specifies the origin of the service associated with the I-SID interface. |
ISID NAME |
Specifies the name of the I-SID. |
BPDU |
Specifies the BPDU forward option for the untagged traffic port. |
MAC SUNI |
Specifies the Switched UNI MAC address. |
The following example shows the configured service instance identifiers (I-SID) on a port.
Switch:1#show interface gigabitEthernet i-sid ======================================================================================= PORT Isid Info ======================================================================================= ISID ISID ISID MAC PORTNUM IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU SUNI ---------------------------------------------------------------------------------------- 1/1 192 27 N/A 4000 ELAN C --- - --- - ISID-27 FALSE 1/1 192 270 N/A 4001 ELAN C --- - --- - ISID-270 FALSE 1/1 192 309 N/A 309 ELAN C --- - --- - ISID-309 FALSE 1/1 192 401 N/A 401 ELAN C --- - --- - ISID-401 FALSE 1/1 192 1001 N/A 1001 ELAN C --- - --- - ISID-1001 FALSE 1/1 192 1111 N/A 1111 ELAN C --- - --- - ISID-1111 FALSE 1/1 192 1121 N/A 1121 ELAN C --- - --- - ISID-1121 FALSE 1/1 192 1201 N/A 1201 ELAN C --- - --- - ISID-1201 FALSE 1/1 192 2001 N/A 2001 ELAN C --- - --- - ISID-2001 FALSE 1/2 193 38 N/A 4000 ELAN C --- - --- - ISID-38 FALSE 1/2 193 310 N/A 310 ELAN C --- - --- - ISID-310 FALSE 1/2 193 380 N/A 4001 ELAN C --- - --- - ISID-380 FALSE 1/2 193 402 N/A 402 ELAN C --- - --- - ISID-402 FALSE 13 out of 152 Total Num of i-sid endpoints displayed ORIGIN Legend: C: manually configured; D: discovered by FA or EPT M: FA management; E: discovered by EAP; A: auto-sense l: discover by local switch r: discover by remote VIST switch