Client Threshold |
Use the spinner to set a client threshold for the Smart
RF policy between 1 - 255. This is the minimum number of
clients a radio should have associated in order for coverage
hole recovery to trigger. The default setting is 1. |
SNR Threshold |
Set a signal-to-noise (SNR) threshold , between 1 - 75
dB. This is the signal-to-noise threshold for an associated
client as seen by its associated access point radio. When
exceeded, the radio increases its transmit power in order to
increase coverage for the associated client. The default
value is 20 dB. |
Coverage Interval |
Define the length of time after
which coverage hole recovery should be initiated when a
coverage hole is detected. The default is 10 seconds for
both the 2.4 and 5.0 GHz radios. |
Interval |
Define the length of time coverage
hole recovery should be conducted before a coverage hole is
detected. The default is 30 seconds for both the 2.4 and 5.0
GHz radios. |