Fabric Level Physical Topology Health
    
    
        The fabric level physical topology
            health is calculated based on the fabric level errors of the topology.
     
        The Physical topology health is divided into two parts:
        
            - Fabric level physical topology
                health: It is used to calculate a fabric health.
 
            - Device level physical topology
                health: It is used to calculate a device operational state health.
 
        
        Fabric Level Physical Topology
                Validations for non-Clos Fabric
            
            
                - Ensure that each rack must have two devices.
 
            
        
        Non-Clos Fabric Level Topology Error Scenarios
            
            
                - Only one device is present in the rack
 
            
        
        Fabric Level Physical Topology Validations for Clos Fabric
            
            
                - Ensure that the stage 3 fabric
                    contains at least one leaf or border leaf and spine device.
 
                - Ensure that the stage 5 fabric
                    contains at least one leaf or border leaf and super-spine devices
 
            
        
        Clos Fabric Level Topology Error Scenarios
            
            
                - For 3-stage Clos fabric:
                        - No leaf or border leaf
                            devices in fabric
 
                        - No spine devices in the
                            fabric
 
                    
 
                - For 5-stage Clos fabric:
                        - No leaf or border leaf
                            devices in fabric
 
                        - No Super-spine devices in
                            the fabric 
 
                    
 
            
            If the topology is invalid, the fabric level physical topology health gets degraded
                or else it is healthy.