You can configure the threshold
            monitor
            options.
     
        About this task
Follow this procedure to configure
            threshold monitor
                options.Table 1. Drift Reconcile & Idempotency Support Table
                        
                            | Identify Drift  | 
                            Reconcile configuration | 
                            Idempotency | 
                        
                    
                        
                            | Yes | 
                            Yes | 
                            Yes | 
                        
                    
For information about commands and supported parameters to configure
                threshold monitor options, see 
    ExtremeCloud Orchestrator Command Reference,
     3.5.0
   .
        Procedure
                Run the following command to set
                    the threshold monitor options:
                
             
        Example
            
                - The following example sets the
                    threshold-monitor hardware-resources interval and count to 60 and 3
                    respectively. These values apply to the following types: bfd-session, lif,
                    mac-table, vxlan-tunnel, route, host, nexthop, and
                    ecmp.
efa inventory device threshold-monitor set –-type hardware-resources --ip 10.10.10.153-154 --interval 60 --count 3
 
                - The following example sets a CPU
                    threshold-monitor to trigger an SNMP event when the CPU threshold of 80% is
                    exceeded. Ensure that the threshold must be exceeded three times (retry) with a
                    polling interval of 60 seconds for the event to be triggered. This means that it
                    would take three minutes before the notification is
                    sent.
efa inventory device threshold-monitor set –-type cpu --ip 10.10.10.153-154 –-actions snmp -–high-limit 80 --retry 3
 
                - The following example sets a
                    mac-table threshold-monitor to trigger an SNMP event when either the high-limit
                    threshold of 80% or the low-limit threshold of 50% is exceeded. Events can be
                    generated for the threshold exceeding the 80% (high) or 50% (low)
                    limits.
efa inventory device threshold-monitor set –-type mac-table --fabric fabric1 –-actions snmp -–high-limit 80 -–low-limit 50