Power Specifications

This topic describes power supply specifications, power consumption, and heat dissipation. Refer to the VSP 4900 Series Data Sheet for up-to-date information.

Power Supply Specifications

109531095110941XN-ACPWR-2000W-F*
Voltage Input Range (Nominal)100-127 / 200-240 VAC100-127 / 200-240 VAC100-127 / 200-240 VAC100-127 / 200-240 VAC
Line Frequency Range50 to 60 Hz50 to 60 Hz50 to 60 Hz50 to 60 Hz
Power Supply Input SocketIEC/EN 60320 C14IEC/EN 60320 C16IEC/EN 60320 C16IEC/EN 60320 C16
Power Cord Input PlugIEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15
Operating Temperature0˚C to 55˚C (32˚F to 131˚F)

Normal Operation

0˚C to 50˚C (32˚F to 122˚F)

Normal Operation

0˚C to 50˚C (32˚F to 122˚F)

Normal Operation

0˚C to 55˚C (32˚F to 131˚F)

Normal Operation

*200-240 VAC is required to achieve full 2000W output. If run at 100-120 VAC, output is limited to 1100W.

XN-ACPWR-350W-FBXN-ACPWR-715W-FBXN-ACPWR-1100W-FBXN-ACPWR-2000W-FB*
Voltage Input Range (Nominal)100-240 VAC100-240 VAC100-240 VAC100-240 VAC
Line Frequency Range50 to 60 Hz50 to 60 Hz50 to 60 Hz50 to 60 Hz
Power Supply Input SocketIEC/EN 60320 C14IEC/EN 60320 C16IEC/EN 60320 C16IEC/EN 60320 C16
Power Cord Input PlugIEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15IEC/EN 60320 C15
Operating Temperature0˚C to 55˚C (32˚F to 131˚F)

Normal Operation

0˚C to 55˚C (32˚F to 131˚F)

Normal Operation

0˚C to 50˚C (32˚F to 122˚F)

Normal Operation

0˚C to 50˚C (32˚F to 122˚F)

Normal Operation

*200-240 VAC is required to achieve full 2000W output. If run at 100-120 VAC, output is limited to 1100W.

Note

Note

XN-ACPWR-xxx-FB PSUs cannot be used with the 10941, 10951, 10953, or XN-ACPWR-2000W-F PSUs on the same switch.
The following are the minimum software versions that are required for use with XN-ACPWR-xxx-FB PSUs and the switch:
  • EXOS version 31.3.1
  • VOSS version 8.3

Previous software versions are not supported with XN-ACPWR-xxx-FB PSUs. You must upgrade to the listed minimum software version or later to use any of the XN-ACPWR-xxx-FB PSUs with the switch.

The following table lists supported PSU combinations when dual redundant PSUs are used on the switch.

Refer to the VSP 4900 Series Data Sheet for appropriate PSUs for the switch.

Table 1. PSU Redundancy Compatibility Notes
Switch ModelPrimary PSUSecondary PSU
Non-PoE models

XN-ACPWR-350W-FB

XN-ACPWR-350W-FB

PoE models

XN-ACPWR-715W-FB or XN-ACPWR-1100W-FB or XN-ACPWR-2000W-FB

XN-ACPWR-715W-FB or XN-ACPWR-1100W-FB or XN-ACPWR-2000W-FB

PoE Power Budget

Switch Model1 x 715W PSU2 x 715W PSU1 x 1100W PSU2 x 1100W PSU1 x 2000W @

200-240 VAC

1 x 2000W @

100-120 VAC

2 x 2000 @

200-240 VAC

2 x 2000W @

100-120 VAC

VSP4900-48P460W1045W845W1440W1440W845W1440W1440W
VSP4900-12MXU-12XETBD720W720W720W720W720W720W720W

Minimum/Maximum Power Consumption and Heat Dissipation

Switch ModelMinimum Power Consumption (W)Minimum Heat Dissipation (BTU/hr)Maximum Power Consumption (W)*Maximum Heat Dissipation (BTU/hr)**
VSP4900-48P7425417461046
VSP4900-24S52179173590
VSP4900-24XE80271207707
VSP4900-12MXU-12XE73250970854