Connecting the E4G-200 Router to DC Power

Before you connect the DC input cable to the power input socket on the E4G-200 router, the DC input cable must be properly connected to the DC source voltage at your facility by a qualified electrician.

Caution

Caution

Connect the DC input cable to a DC main circuit breaker rated no greater than 15A. Provide proper connection and strain relief on the DC input cable in accordance with all local and national electrical codes.
  1. Verify that the DC circuit is de-energized.
  2. Align the power cable connector with the power input connector on the router and press the connector firmly into place.
  3. Align and securely tighten the retaining screws on the connector, as shown in the following figure.
    Caution

    Caution

    Make sure the retaining screws are securely tightened to prevent accidental removal of the power connector.

    Click to expand in new window
    Connecting the DC Input Cable
    ../Graphics/CSR_019_E4G200_connect_DC.svg
  4. Energize the DC circuit.