Connecting the Ground Cable
You must ground the DC power supply before
connecting it to a power source.
Warning
Connect the ground cable before you connect any power
cables.
Warning
Disconnect the ground cable after you disconnect all power cables.
-
Verify that the DC circuit is de-energized.
-
Identify the grounding point on the front panel of the
power supply.
-
Insert an M3.5 screw (provided) through the ring
terminal on the ground cable and into the grounding point on the power
supply.
See the following figures.
Connecting the Ground Cable (Model
10933)
1 = Grounding point |
2 = Ground cable |
Connecting the Ground Cable (Model
10934A)
1 = Grounding point |
2 = Ground cable |
-
Tighten the screw to 12.6 pound-inches (1.42
Newton-meters).
-
Connect the other end of the cable to a known
reliable earth ground point at your site.