Use the following commands to configure a CFM segment.
Some of these commands are optional and, if not configured, the default values are used. The following table lists the default values for delay measurement for a CFM segment.
Default Values for Delay Measurement for a CFM Segment
| Configuration | Default Values |
|---|---|
|
Transmit interval |
10 seconds |
|
Window |
60 frames |
|
Timeout |
50 milliseconds |
|
Alarm threshold |
10% |
|
Clear threshold |
95% |
|
Dot1p priority |
6 |
Default Values for Loss Measurement for a CFM Segment
| Configuration | Default Values |
|---|---|
|
LMM Transmit interval |
90 seconds |
|
Dot1p priority |
6 |
|
Window |
1200 frames |
|
SES threshold |
0.01 |
|
Consecutive available count |
4 |

Note
The statistics for a particular transmission are preserved until the user triggers the transmission once again or if clear counters cfm segment is triggered from the CLI.