CFM over double tagged end-points

This feature enables CFM Maintenance End Point (MEP) on the double tagged VPLS/VLL end-point.

Domain double-tagged support for CFM enables up and down MEP at a double-tagged provider edge. For a Bridge Domain double tagged port to advertise CFM, the CLI command must specify the inner VLAN while configuring the MEP using the mep command as follows.

For more information on the command, please refer the SLX-OS Command Reference guide.

The show cfm command displays the inner vlan-id for MEP as follows.

device# show cfm
Domain: dom1
Level: 5
  Maintenance association: ma1
  MA Index: 4
  CCM interval: 10000 ms
  Bridge-Domain ID: 100 
  Priority: 4
  MEP   Direction  MAC              PORT        VLAN     PORT-STATUS-TLV
  ====  =========  =========        ====        =======  ===============
  11    DOWN       768e.f80a.9903   Eth 2/15    100,200       N
The show cfm connectivity command displays the inner vlan-id for the remote MEP as follows.
SLX# show cfm connectivity
Domain: dom1
Level: 5
  Maintenance association: ma1
  MA Index: 4
  CCM interval: 10000
  Bridge-Domain ID: 100
  Priority: 4
  MAID Format: Short
    MEP Id: 2
    MEP Port: Eth 1/5
      RMEP     MAC             		VLAN/PEER            PORT        STATE
      ==== 	 ===             		=========              ====         =====
      3     	 0010.9400.0002    	100,200               Eth 1/5        OK