Switch Fabric Module (SFM), and Traffic Manager (TM) error interrupts are logged in RASLOG.
FE Health Monitoring
device(config)# sysmon fe-access-check ? Possible completions: action Set Fe-Access-Check action disable Disable Fe Access Check (Default: Enabled) poll-interval Set Fe-Access-Check poll-interval recovery-threshold Set Fe-Access-Check recovery threshold threshold Set Fe-Access-Check threshold device(config)#
SFM Walk
device(config)# sysmon sfm-walk ? Possible completions: auto Enable Auto SFM Walk (Default: Disabled) disable-redundancy-check Disable SFM Walk redundancy check (Default: Enabled) poll-interval Set SFM Walk poll-interval threshold Set SFM Walk reassembly error threshold device(config)#
Use the sysmon sfm-walk command to manually start or stop SFM walk.
device# sysmon sfm-walk ? Possible completions: start Start SFM Walk stop Stop SFM Walk device#
FE Link CRC Monitoring
device(config)# sysmon link-crc-monitoring ? Possible completions: action Set Link CRC Monitoring action disable Disable Link CRC Monitoring (Default: Enabled) poll-interval Set Link CRC Monitoring poll-interval threshold Set Link CRC Monitoring threshold device(config)#
Show commands
Following are sample show command outputs for the SFM module.
device# show sfm ? Possible completions: link-connectivity Display fabric connectivity link-thresholds Display fabric thresholds links Display fabric links mcast Display fabric mcast entries queue-occupancy Display fabric queues serdes-mode Display fabric serdes-mode statistics Display fabric global counters
device# show sfm link-connectivity SFM Connectivity (FE 4): -------------------- Link | Logical Port | Remote Module | Remote Link | Remote Device Type ---------------------------------------------------------------------- 036 | 036 | 0012 | 011 | FAP 037 | 037 | 0012 | 009 | FAP 038 | 038 | 0012 | 010 | FAP 039 | 039 | 0012 | 008 | FAP
device# show sfm queue-occupancy FE Queue (FE 4): DCH Queues: ========= DCH0 Pipe 0: [22,9] DCH1 Pipe 0: [59,6] DCH2 Pipe 0: [64,8] DCH3 Pipe 0: [136,6] DCL Queues: ========= DCL0 Pipe 0: [20,4] DCL1 Pipe 0: [56,12] DCL2 Pipe 0: [136,4]
device# show sfm link-thresholds Link | Pipe | GCI1 | GCI2 | GCI2 RX Thresholds: 001 | 000 | 0511 | 511 | 511 TX Thresholds: 001 | 000 | 0024 | 032 | 40
device# show sfm links FE-LINKS: FE Links (FE 4): Link | CRC Error | Size Error | Code Group Error | Misalign | No Signal Lock | No signal accept | Errored tokens | Errored tokens count ---------------------------------------------------------------------------------------------------------------------------------------- 0 | - | - | *** | *** | *** | *** | *** | 0 1 | - | - | *** | *** | *** | *** | *** | 0 2 | - | - | *** | *** | *** | *** | *** | 0 3 | - | - | *** | *** | *** | *** | *** | 0 4 | - | - | - | - | - | - | - | 63 5 | - | - | - | - | - | - | - | 63 6 | - | - | - | - | - | - | - | 63
device# show sfm mcast id 1 For MGID 1 fap-list: idx:1 fap-id:0x0 For MGID 1 fap-list: idx:2 fap-id:0x1 For MGID 1 fap-list: idx:3 fap-id:0x2 For MGID 1 fap-list: idx:4 fap-id:0x3
device# show sfm statistics #-----------------------------------------------------------------------# # | Pipe 0 # #-----------------------------------------------------------------------# # DCH: | # # Total Incoming Cells | 0 # # Total Outgoing Cells | 0 # # Fifo Discard | 0 # # Reorder Discard | 0 # # Unreach Discard | 0 # # Max Cells in Fifos | 0 # #-----------------------------------------------------------------------# #-----------------------------------------------------------------------# # DCM: | # # Total Incoming Cells | 0 # # Dropped Cells | 0 # # Max Cells in Fifos | 0 # #-----------------------------------------------------------------------# #-----------------------------------------------------------------------# # DCL: | # # Total Incoming Cells | 0 # # Total Outgoing Cells | 0 # # Dropped Cells | 0 # # Max Cells in Fifos | 0 # #-----------------------------------------------------------------------# #-----------------------------------------------------------------------#
device# show switch_fabric_module Slot Type Description ID Status ---------------------------------------------------------------------- S1 SFM8 v6 Switch Fabric Module 187 ENABLED S2 SFM8 v6 Switch Fabric Module 187 ENABLED S3 SFM8 v6 Switch Fabric Module 187 ENABLED S4 SFM8 v6 Switch Fabric Module 187 ENABLED S5 SFM8 v6 Switch Fabric Module 187 ENABLED S6 SFM8 v6 Switch Fabric Module 187 ENABLED