Use the information in the following tables to learn about all possible HA alerts in detail that are raised by Fault Management.
31050 | HA Service (Non-Redundant) |
---|---|
Description | Send an alert when the standby node is not up which indicates that the system has no redundancy. |
Preconditions |
Starting with EFA 3.1.0, a timer task periodically monitors the status of the standby node, and raises an event to the fault management system. The fault management system raises an alert to the user to indicate that the system is not fully redundant.
|
Requirements |
Alert shows the following data:
The following example shows an alert when the standby node is
down:
<114> 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.2.0”] [alert@1916 resource=”/App/System/HA/Nodes/Node” alertId=”31050” cause=”lossOfRedundancy” type=”operationalViolation” severity=”major”] [alertData@1916 node_ip=”10.1.2.4”] BOMHA degraded, node 10.1.2.4 is down. |
Health Response |
Response
{ Resource: /App/System/HA/Nodes/Node HQI { Color: Red Value: 3 } StatusText: HA degraded, node 10.2.3.5 is down. } |
31051 | HA Service (Fully Redundant) |
---|---|
Description | Send an alert when the standby node is up and ready which indicates that the system is fully redundant. |
Preconditions |
A timer task periodically monitors the status of the nodes and raises an event to the fault management system. The fault management system raises an alert to the user to indicate that the system is fully redundant.
|
Requirements |
Alert shows the following data:
The following example shows an alert when the standby node is up
and running:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.2.0”] [alert@1916 resource=”/App/System/HA/Nodes/Node” alertId=”31051” cause=”redundancyRestored” type=”operationalViolation” severity=”info”] BOMHA fully redundant |
Health Response |
Response
{ Resource: /App/System/HA/Nodes/Node HQI { Color: Green Value: 0 } StatusText: HA fully redundant. } |
31052 | HA Service (Failover Occurred) |
---|---|
Description | Send an alert when an HA failover has occurred. |
Preconditions |
A timer task periodically monitors the status of the nodes and raises an event to the fault management system. The fault management raises an alert to the user to indicate that an HA failover has occurred.
|
Requirements |
Alert shows the following data:
The following example shows an alert when there is a HA
failure:
<114>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.2.0”] [alert@1916 resource=”/App/System/HA/Nodes/Node” alertId=”31052” cause=”localNodeTransmissionError” type=”operationalViolation” severity=”major”] [alertData@1916 active_iP=”10.1.2.3”] BOM10.1.2.3 is now the HA active node |
Health Response |
Response
{ Resource: /App/System/HA/Nodes/Node HQI { Color: Red Value: 3 } StatusText: 10.1.2.3 is now the HA active ndoe. } |
31053 | Service Degraded |
---|---|
Description | Send an alert when some of the node services are not operational. |
Preconditions | A timer task periodically monitors the node status and raises an
event to the fault management system. The fault management system
raises an alert to the user to indicate that some of the node
services are not running.
|
Requirements | Alert shows the following data:
The following example shows an alert when some of the
node services are not
running:
<116>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.2.0”] [alert@1916 resource=”/App/System/HA/Nodes/Services” alertId=”31053” cause=”serviceDegraded” type=”operationalViolation” severity=”warning”] BOMSome of the services are not operational. |
Health Response | Response{ Resource: /App/System/HA/Nodes/Services HQI { Color: Yellow Value: 1 } StatusText: Some of the services are not operational. } |
31054 | Service Restored |
---|---|
Description | Send an alert when all the node services are operational. |
Preconditions | A timer task raises an event to the fault management system. The
fault management system raises an alert to indicate to the user that
some of the node services are running.
|
Requirements |
Alert shows the following data:
The following example shows an alert when all the node services
are
running:
<118>1 2003-10-11T22:14:15.003Z xco.machine.com FaultManager - - [meta sequenceId=”47”] [origin ip=”10.20.30.40” enterpriseId=”1916” software=”XCO” swVersion=”3.2.0”] [alert@1916 resource=”/App/System/HA/Nodes/Services” alertId=”31054” cause=”serviceRestored” type=”operationalViolation” severity=”info”] BOMServices are in running state. |
Health Response | Response{ Resource: /App/System/HA/Nodes/Services HQI { Color: Green Value: 0 } StatusText: Services are in running state. } |