t5
  
  
    Displays adopted T5 controller
        statistics
Note   
This command is applicable
        only on WiNG controllers with adopted and managed T5 controllers.
Supported in the following platforms:
      
      
        - Service Platforms — NX7500, NX9500,
          NX9600, VX9000
Syntax
      
      show t5 [boot|clock|cpe|interface|mac|system|temperature|uptime|version|
wireless] {on <T5-DEVICE-NAME>}
      show t5 [boot|clock|system|temperature|uptime|version] {on <T5-DEVICE-NAME>}
      show t5 cpe [address|boot|ether port status|led|reset|system|uptime|version] 
{on <T5-DEVICE-NAME>}
      show t5 interface [dsl|fe|ge|radio]
      show t5 interface [dsl|fe|ge] [counter|description|errors|status|utilization] {on <T5-DEVICE-NAME>}
      show t5 interface dsl custom [avg|dses|dsses|peak|uses|usses] {on <T5-DEVICE-NAME>}
      show t5 interface radio [stats|status|wlam-map] {on <T5-DEVICE-NAME>}
      show t5 mac table [filter name [dsl<1-24>|ge <1-2>|vlan <1-4094>|wlan <1-24>] {on <T5-DEVICE-NAME>}
      show t5 wireless [client|wlan]
      show t5 wireless client {filter name [association-status|authentication-status|
bss|mac-address|retry-percentage|rssi-value]} {on <T5-DEVICE-NAME>}
      show t5 wireless wlan counters [qos|rate|size] {on <T5-DEVICE-NAME>}
    
    Parameters
      
      show t5 [boot|clock|system|temperature|uptime|version] {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | boot | Displays the T5 device‘s boot details. Use this option to view the primary and
                secondary image files available to use for booting up. | 
            
              | clock | Displays the T5 controller‘s system time, as reported from the controller
                itself or its remote NTP time resource | 
            
              | system | Displays T5 controller‘s system information, which includes the T5 controller‘s
                hostname, MAC address, RF Domain, system clock, uptime | 
            
              | temperature | Displays T5 controller‘s current temperature | 
            
              | uptime | Displays the T5 controller‘s uptime (the time it has been actively deployed and
                operational) | 
            
              | version | Displays the T5 controller‘s primary and secondary firmware images | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 cpe [address|boot|ether port status|led|reset|system|uptime|version] 
{on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | cpe | Displays the T5 controller managed Customer Premises Equipment
                (CPE) statistics based on the parameters passed. Use this command to verify
                each CPE address credentials and whether currently disconnected or ready for radio
                coverage area support. | 
            
              | address | Displays each linked CPE's current IP address used as its network
                identifier | 
            
              | boot | Displays the primary and secondary firmware versions available to each CPE,
                along with status of the most recent upgrade operation details | 
            
              | ether port status | Displays Ethernet port status | 
            
              | led | Displays whether the CPEs currently have their LEDs enabled or disabled. In
                places like hospitals, its not uncommon for access points to be operational, but
                their LEDs off as to not disturb patients. | 
            
              | reset | Displays the number times a CPE has been reset | 
            
              | system | Displays device hardware and SKU information for each CPE. Use this information
                to assess whether a controller is managing the correct CPE devices out of the total
                number of CPEs available. | 
            
              | uptime | Displays the time each CPE device has been actively deployed and
                operational | 
            
              | version | Displays the application and boot versions utilized by the CPE devices | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 interface [dsl|fe|ge] [counter|description|errors|status|utilization] {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | interface | Displays T5 interface-related statistics based on the interface
                selected | 
            
              | [dsl|fe|ge|radio] [counter|description| errors|status| utilization] | Select the interface type. The options are: dsl,
                  fe, and ge. 
                  dsl – Displays Digital Subscriber Line
                    (DSL) interface related informationfe – Displays Fast Ethernet (FE)
                    interface related informationge – Displays Gigabit Ethernet (GE)
                    interface related information The system displays the following information for the DSL, GE, and FE
                    ports: 
                    counter – Displays the
                        following:
                        Number of octets (bytes)
                          received and transmitted on this portNumber of data packets
                          received and transmitted on this portNumber of flow control
                          (layer 2) packets received and transmitted on this portdescription – Displays the
                        following:
                        The selected port‘s
                          nameThe numeric index
                          assignable to each portThe 64 character maximum,
                          unique, administrator-assigned description to each porterrors – Displays the
                      following DSL interface related errors:
                        The name of the DSL
                          utilized by each T5 controller connected CPE deviceThe number of FECs
                          detected in the downstream direction. Forward Error Correction
                          (FEC) or channel coding is used for controlling errors over
                          unreliable or noisy communication channels.The number of CPE DSL
                          coding violations (badly coded packets) detected in the downstream
                          direction.The number of FECs
                          detected in the upstream direction.The number of CPE DSL
                          coding violations (badly coded packets) detected in the upstream
                          direction.status – Displays the
                        following:
                        The selected port‘s
                          nameWhether the port is
                          currently up or down as a T5 controller transmit and receive resourceThe port's current speed
                          in MBWhether pause packet
                          utilization is currently off or on for the selected portWhether each listed port
                          is enabled or disabled by the administratorutilization – Displays the
                        following:
                        The selected port‘s
                          nameThe port‘s receive and
                          transmit data rates (in Kbps)The packet per second
                          port receive and transmit rates (p/s)Each port's receive and
                          transmit direction utilization as a percentage of the total transmit
                          bandwidth available. | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T% device
                    name is specified. | 
          
      show t5 interface dsl custom [avg|dses|dsses|peak|uses|usses] {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | interface | Displays T5 interface-related statistics based on the interface
                selected | 
            
              | dsl | Selects A T5 controller‘s DSL interface. A T5 controller uses the operating
                  system to manage its connected radio devices, as opposed to the WiNG operating
                  used by controllers and service platforms. However, a T5 controller, once enabled
                  as a supported external device, can provide data to WiNG to assist in a T5‘s
                  management within a WiNG supported subnet populated by both types of devices. The
                  CPEs are the T% controller managed radio devices using the operating system. These
                  CPEs use a DSL as their high speed Internet access mechanism using the CPE‘s
                  physical wallplate connection and phone jack. | 
            
              | custom [avg|dses|dsses|peak|uses|usses] | Displays following custom CPE DSL data: 
                  avg – Each DSL's average
                    response time in microsecondsdses – The number of seconds
                    downstream DSL transmissions were negatively impacted by code violations.dsses – The number of seconds
                    downstream DSL transmissions were severely negatively impacted by code
                    violations.peak – Each DSL's maximum (best
                    to date since the screen was refreshed) response time in microseconds.uses – The number of seconds
                    upstream DSL transmissions were negatively impacted by code violations.usses – The number of seconds
                    upstream DLS transmissions were severely negatively impacted by code
                    violations. | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 interface radio [stats|status|wlam-map] {on <T%-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | interface | Displays T5 interface-related statistics based on the interface
                selected | 
            
              | radio [stats|status| wlan-map] | Displays following radio interface related
                  information: 
                  stats – Displays T5 radio
                    interface statistics. A T5 controller uses the operating system to manage its
                    connected radio devices, as opposed to the WiNG operating used by controllers
                    and service platforms. However, a T5 controller, once enabled as a supported
                    external device, can provide data to WiNG to assist in a T5‘s management within
                    a WiNG supported subnet populated by both types of devices. The CPEs are the T5
                    controller managed radio devices using the operating system. Use this option to
                    view the following:
                      name – The administrator
                        assigned name of each listed CPE radio as its unique identifierRx (Kbps) – The listed CPE
                        radio's receive data rate (in Kbps). Use this information to assess RF
                        activity versus other T5 managed CPE radios in the same radio coverage
                        area.Rx Octets – The number of
                        octets (bytes) received with no errors by the listed T5 controller managed
                        CPE radio.Rx Packets – The number of
                        data packets received for the listed T5 managed CPE radio since this screen
                        was last refreshed.Tx (Kbps) – The listed CPE
                        radio's transmit data rate (in Kbps). Use this information to assess RF
                        activity versus other T5 managed CPE radios in the same radio coverage
                        area.Tx Octets – Displays the
                        number of octets (bytes) transmitted with no errors by the listed T5
                        controller managed CPE radio.Tx Packets – The number of
                        data packets transmitted from the listed T5 managed CPE radio since this
                        screen was last refreshed.status – Displays T5 radio
                    interface status information
                      name – The administrator
                        assigned name of each listed CPE radio as its unique identifier.Operational status – The
                        radio interface‘s operational status (enabled/disabled).mac – The T5 radio
                        interface's MAC address.transmit power – The T5
                        radio interface‘s transmit power.Channel – The T5 radio
                        interface‘s channel of operation.wlan-map – Displays WLAN map
                    membership data for T5 controller managed CPE radio devices. Use this option to
                    view the following:
                      name – The administrator
                        assigned name of each listed CPE radio as its unique identifier.status – Whether a CPE
                        radio is currently enabled or disabled as a radio resource for the WLAN(s)
                        the CPE radio has been mapped to.wlan-radio-mapping – The
                        managed WLAN(s) each listed radio has been mapped to. | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 mac table [filter name [dsl<1-24>|ge <1-2>|vlan <1-4094>|wlan <1-24>] {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | mac table [dsl<1-24>|ge <1-2>| vlan <1-4094>|
                wlan <1-24>] | Displays T5 MAC address table. The T5 MAC table displays a dynamic list of MAC
                addresses learned by the T5 controller over its ethernet interfaces. Use this
                information to identify devices and the interfaces on which they can be found. Use
                  the following additional filters to filter on the basis of the VLAN or DSL
                    interface: 
                    dsl <1-24> – Filters
                      information on the basis of the selected DSL portge <1-2> – Filters
                      information on the basis of the selected GE portvlan <1-4094 – Filters
                      information on the basis of the selected VLAN portwlan <1-24> – Filters
                      on the basis of the selected CPE | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 wireless client {filter name [association-status|authentication-status|bss|
mac-address|retry-percentage|rssi-value]} {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | wireless client | Displays the T5 wireless client and WLAN related statistics 
                  client – Displays read-only
                    device information for wireless clients associated with the selected T5
                    controller and its connected CPE device radios. Use this information to assess
                    if configuration changes are required to improve client performance. Use the additional filters available to view specific client-related
                  information. The options are: 
                    association-statusauthentication-statusbssretry-percentagerssi-value | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
      show t5 wireless wlan counters [qos|rate|size] {on <T5-DEVICE-NAME>}
      
            
              | t5 | Displays adopted T5 controller statistics | 
            
              | wireless wlan [qos|rate|size] | Displays the T5 wireless WLAN related statistics 
                  wlan – Displays following T5
                    controller traffic counter statistics:
                      qos – Displays T5
                        controller WLAN QoS utilization. Displays the number of background (low
                        priority) and best-effort packets received and transmitted on each listed T5
                        controller managed WLANsrates – Displays T%
                        controller's WLAN utilization data rate statistics
                          Lists the number of
                            data packets received and transmitted in the WLAN that have been
                            relegated to a 1 Mbps data rateLists the number of
                            data packets received and transmitted in the WLAN by T5 controller
                            connected devices at 54Mbpssize – Displays the number
                        of data packets received and transmitted, in each listed WLAN, greater than
                        1024 bytes | 
            
              | on <T5-DEVICE-NAME> | Optional. Executes the command on a specified T5 device 
                  <T5-DEVICE-NAME> –
                    Specify the T5 device‘s hostname. An error message is displayed if no T5 device
                    name is specified. | 
          
    
    Examples
      
      The following examples are for show commands executed on the ‘t5-ED7C6C‘ controller adopted
        by the ‘nx9500-6C8809‘ wireless controller:
      nx9500-6C8809(config)#show t5 boot on t5-ED7C6C
Primary Version:  5.4.2.0-010R
Secondary Version:  5.4.2.0-006B
Next Boot: Primary
Upgrade Status: none
Upgrade Progress %:  0
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 version on t5-ED7C6C
Bootloader Version:   5.4.2.0-010R
Application Version:  5.4.2.0-010R
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 system on t5-ED7C6C
Serial Number           14213522400004
SKU                     TS-0524-WR
Hardware Rev            5
Mac Address             B4-C7-99-ED-7C-6C
Description             24-port PowerBroadband VDSL2 Switch Version 5.4.2.0-010R
Contact                 NULL
Name                    t5-ED7C6C
Location                NULL
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 clock on t5-ED7C6C
Time 6-6-2017 17:14:30 UTC
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 interface ge counter on t5-ED7C6C
-------------------------------------------------------------------------------------------------------------------
 INTERFACE RECEIVE OCTETS RECEIVE PACKETS RECEIVE PAUSE PKTS TRANSMIT OCTETS TRANSMIT PACKETS TRANSMIT PAUSE PKTS
-------------------------------------------------------------------------------------------------------------------
  ge1       711128918     89636040         0                  2558110037     133720283         0
  ge2       2515775064    133311355        0                  3422167586     78735853          0
-------------------------------------------------------------------------------------------------------------------
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 uptime on t5-ED7C6C
Up Time 0 days 1 day, 3:19:43
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 temperature on t5-ED7C6C
============ Temperature  ============
--------------------------------------------------------------------
 INDEX CURRENT (C) FANS @ FULL SPEED (C) FANS @ VARIABLE SPEED (C)
--------------------------------------------------------------------
 1      39          70                    60
--------------------------------------------------------------------
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 cpe address on t5-ED7C6C
--------------------------------------------------------------------------------            
DEVICE             STATUS             IP ADDRESS                MAC ADDRESS
--------------------------------------------------------------------------------            
 cpe1             ready             192.168.13.32            00-C0-23-69-80-CD
 cpe2             ready             192.168.13.33            74-6F-F7-40-16-62
 cpe3             disconnected      0.0.0.0                  00-00-00-00-00-00
 cpe4             disconnected      0.0.0.0                  00-00-00-00-00-00
 cpe5             disconnected      0.0.0.0                  00-00-00-00-00-00
--More--
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 cpe led on t5-ED7C6C
---------------------------------------------------------------------------------------
 DEVICE                                 LED STATUS             
-----------------------------------------------------------------------------------
 cpe1                                    enable                                      
 cpe2                                    enable                                      
 cpe3                                    enable                                      
 cpe4                                    enable                                      
 cpe5                                    enable                                      
--More--
nx9500-6C8809(config)#
      nx9500-6C8809(config)#show t5 mac table filter name vlan 1 on t5-ED7C6C
---------------------------------------------------------------------------------------
        T5-MAC       VLAN          ADDRESS             INTERFACE                VENDOR
---------------------------------------------------------------------------------------
 B4-C7-99-ED-7C-6C   1              00-02-B3-28-D1-55    ge1                    Intel Corp
 B4-C7-99-ED-7C-6C   1              00-1E-67-4B-BF-BD    ge1                    Intel Corp
 B4-C7-99-ED-7C-6C   1               00-23-68-11-E6-C4    ge1                    Extreme Tech
 B4-C7-99-ED-7C-6C   1               00-23-68-88-0D-A7    ge1                    Extreme Tech
 B4-C7-99-ED-7C-6C   1               00-23-68-99-BB-7C    ge1                    Extreme Tech
 B4-C7-99-ED-7C-6C   1               00-A0-F8-68-D5-70    ge1                    Extreme Tech
 B4-C7-99-ED-7C-6C   1             00-C0-23-69-80-CD    dsl1                   00-C0-23 
 B4-C7-99-ED-7C-6C   1              1C-7E-E5-18-FA-67     ge1                    D-Link Corp
 B4-C7-99-ED-7C-6C   1                3C-CE-73-F4-47-83     ge1                    Cisco Systems
 B4-C7-99-ED-7C-6C   1               74-6F-F7-40-16-62     dsl2                   Wistron Corp
--More--
nx9500-6C8809(config)#