t5 (management-policy)
  
    Configures SNMP
      server settings for T5 devices on this management policyA T5 controller
        is an external device that can be adopted and managed by a WiNG
        controller. When enabled as a supported external device, the T5
        controller provides data to WiNG to assist in it‘s management within a
        WiNG supported subnet.
This command enables SNMP to communicate
        with T5 devices within the network. SNMP facilitates the exchange of
        management information between the controller or service platform and
        the T5 device. For more information, see snmp-server.
    Supported in the following platforms:
      
      
        - Service Platforms —
          NX9500, NX9600
Syntax
      
      t5 snmp-server [community|contact|enable|host|location]
      t5 snmp-server community <COMMUNITY-NAME> [ro|rw] <SNMP-STATION-IP>
      t5 snmp-server contact <LINE>
      t5 snmp-server enable [server|traps]
      t5 snmp-server host <IP>
      t5 snmp-server location <LINE>
    
    Parameters
      
      t5 snmp-server [community|contact|enable|host|location]
      
            
              | community <COMMUNITY-NAME> [ro|rw] | Defines a public or private community designation. By default, SNMPv2 community
                strings on most devices are set to public, for the read-only community string, and
                private for the read-write community string. 
                   <COMMUNITY-NAME> –
                    Specify the SNMP community name, and configure the access permission for this
                    community string (used by devices to retrieve or modify information).
                       ro – Allows a remote
                        device to retrieve information onlyrw – Allows a remote device
                        to retrieve information and modify settings | 
            
              | <SNMP-STATION-IP> | Specify the SNMP management station IP address for receiving trap
                information | 
          
      t5 snmp-server contact <LINE>
      
            
              | contact <LINE> | Configures the administrator of SNMP trap events for the T5 controller. 
                   <LINE> – Specify the
                    administrator‘s name (should not exceed 64 characters). | 
          
      t5 snmp-server enable [server|traps]
      
            
              | enable [server|traps] | Enables the following: 
                  server – Enables the SNMP
                    server. When enabled, the system accepts SNMP management data. This option is
                    enabled by default. traps – Enables SNMP traps.
                    When enabled, the system generates SNMP traps. This is enabled by default. | 
          
      t5 snmp-server host <IP>
      
            
              | host <IP> | Configures the T5 SNMP host‘s IP address. The SNMP host receives the SNMP
                notifications. 
                  <IP> – Specify the SNMP
                    host‘s IP address. | 
          
      t5 snmp-server location <LINE>
      
            
              | location <LINE> | Configures the system location for SNMP traps 
                  <LINE> – Specify the SNMP
                    trap location (should not exceed 64 characters). | 
          
    
    Example
      
      nx9500-6C8809(config-management-policy-test)#t5 snmp-server community lab rw 192.168.13.7
      nx9500-6C8809(config-management-policy-test)#show context
management-policy test
 http server
 no ssh
 t5 snmp-server community lab rw 192.168.13.7
nx9500-6C8809(config-management-policy-test)#
    
    Related Commands
      
      
            
              | no | Removes or reverts SNMP server configuration for T5
                devices |