Preparing the DC Cables
Before connecting the E4G-400 router to DC
power, prepare the DC cables.
The following terminals are provided
with the power supply.
- Two spade terminals (Tyco part number 328281 or
equivalent) for connecting the input power cables
- One ring terminal (Tyco part number 2-320561-4 or
equivalent) and screw with captive lock washer (type 6-32 UNC) for
connecting the ground cable
You need a crimping tool to attach the terminals to
the power and ground cables.
-
On each wire, strip 0.25 inch (6.4 mm) of
insulation from one end.
-
Insert the stripped end of the input power cable
end all the way into the barrel of a spade terminal.
Crimp the terminal securely to the cable.
-
Insert the stripped end of the green/yellow ground
cable end all the way into the barrel of the ring terminal.
Crimp the terminal securely to the
cable.
Refer to the following figure.
Attaching Terminals to Cables
| Power connection wire |
Ground wire |