Summit X450, X450a, and X450e Series Switch LEDs

The following sections describe the meanings of the LEDs on the Summit X450, X450a, and X450e series switches.

Click to expand in new window

Front Panel

Label or Type Color/State Meaning
MGMT Blinking green (fast) Power-on self-test (POST) in progress.
Steady green POST passed. System is booting image.
Blinking green (slow) Normal operation
Blinking amber Switch diagnostics running.

or

System is disabled. POST failed or system overheated.

Off No external power attached.
FAN Steady green Normal operation
Steady amber* A single fan in the array has failed. The switch can continue to operate indefinitely.

1

Blinking amber Failure

or

Two or more fans in the array have failed. Because system cooling is compromised, you should replace the switch.*

Off No power
PSU-I

(Internal power supply)

Steady green Normal operation
Blinking amber Failure
Off No power
PSU-E

(External power supply)

Steady green Normal operation
Blinking amber Failure
Off No external power attached.
Ethernet Ports

1 – 24 or 1 – 48

(21 – 24 and 45 – 48 are shared ports)

Steady green Link OK
Blinking green Activity
Off Link is not present or port is disabled.
Stack Number Indicator Top half of number blinking This switch is the stack master.
Lower half of number blinking This switch is the stack backup.
Number lights steadily This switch is a standby node (neither the master nor the backup).
LED dark This stackable switch is not in stacking mode.
Click to expand in new window

Additional Port LED meanings for PoE switches: Summit X450e-24p & Summit X450e-48p

Label or Type Color/State Meaning
All front-panel ports Steady amber Port is powered with link, with no traffic.
Blinking amber Port is powered with link, with traffic.
Slow blinking amber Port is powered, with no link.
Alternating amber and green Port has a fault.

Off

Port is not powered, has no link, or is disabled.

Click to expand in new window

Rear Panel

Label or Type Color/State Meaning
Management Port Steady green Link OK
Blinking green Activity
Stacking Port Steady green Link OK
Blinking green Activity
SFP 1G Port

(on installed option card)

Steady green Link OK
Blinking green Activity
XENPAK 10G Port

(on installed option card)

Steady green Link OK
Blinking green Activity
XFP 10G Port

(on installed option card)

Steady green Link OK
Blinking green Activity

1 These states for the Fan LED occur only on Summit X450a-48tDC switches with a manufacturing part number of 800294-00 and X450a-48tDC-TAA switches with a manufacturing part number of 800337-00.