Connecting Category 6 UTP Ethernet Cables to the BASE-T Ports
The fixed RJ45 front panel
connections of the SSA-T8028-0652 are 10/100/1000 Mbps ports. They have internal
crossovers and support automatic-polarity sensing that eliminates the need for a
crossover cable, regardless of whether the connection is to another network device or a
workstation.
![Note](../../images/Note_Note.png)
Note
All RJ45 front panel ports on the SSA-T8028-0652 support Category 6 Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms.
-
Ensure that the far-end
device connected to the other end of the segment is powered on.
-
Connect the far-end device‘s
twisted pair segment into the appropriate BASE-T port connector on the SSA
switch.
-
Verify that a link exists by
checking that the port RX (Receive) LED is on (flashing amber, blinking green, or
solid green).
If the RX LED is off and the TX (Transmit)
LED is not blinking amber, perform the following steps until the RX LED is on:
-
Verify that the proper cabling is being used: Category 6 UTP with an impedance
between 85 and 111 ohms.
-
Verify that the device at the other end of the twisted pair segment is on and
is properly connected to the segment.
-
Verify that the BASE-T connectors on the twisted pair segment have the proper
pinouts.
-
Check the cable for continuity.
-
Repeat step 1 through step 3 until all connections