Securing the SSA Switch to the Rack

To secure the SSA switch to the rack, follow these steps:

  1. Slide the chassis onto the rail assembly until the chassis adapter plate ears meet the rail assembly ears.
    See Securing the SSA switch to the Rack.
    Click to expand in new window
    Securing the SSA switch to the Rack
    Graphics/ssa_sec_switch_to_rack.png
    1 = Flush mount configuration 3 = Rack-appropriate screws or fasteners (2)
    2 = Mid-mount configuration 4 = Black 10-32 screws (2)
  2. For a flush mount rail assembly configuration, secure each side of the chassis using a user-supplied screw or fastener appropriate to your rack.
  3. For a mid-mount rail assembly configuration, secure each side of the chassis using a black, 10-32 screw that comes with the rack mount kit.
    These screws are screwed into the cage nut installed in the square rail ear opening as described in step 3.