Attach the Access Point to a Pole Using WS-MBO-POLE01 Bracket and MBO-ART02 Articulating Mounting Bracket

Before you begin

Note

Note

The WS-MBO-POLE01 bracket is End of Sale (EOS) as of January, 2023.

The MBO-ART02 wall mount bracket is End of Sale (EOS) as of January, 2023. It is replaced by the MBO-ART03 bracket.

For more information, see End of Sale and End Service Life.

The following hardware is required:
  • WS-MBO-POLE01 bracket
  • MBO-ART02 bracket
  • Two M6 hex-head screws
  • Four M3 screws, nuts, and washers to attach the WS-MBO-POLE01 bracket to the MBO-ART02 articulating mounting bracket
  • Two cable clamps
    Note

    Note

    You need to provide your own stainless-steel cable clamps. The band must be 0.5 in. (12.7 mm) wide.
  • Access point

Procedure

  1. Attach the MBO-ART02 articulating mounting bracket to the access point using two M6 hex-head screws.
  2. Attach the WS-MBO-POLE01 bracket to the MBO-ART02 articulating mounting bracket using four M3 screws, nuts, and washers.
    Click to expand in new window
    POLE01 bracket being attached to the ART02 articulating mounting bracket
    Image of WS-MBO-POLE01 bracket being attached to the MBO-ART02 articulating mounting bracket using four M3 screws, nuts, and washers
  3. Open the cable clamp by turning a flat-bladed screwdriver counterclockwise.
  4. Insert the non-clamp end into the pole bracket through the holes.
  5. Attach both the cable clamps to the WS-MBO-POLE01 bracket.
  6. Place the metal band around the pole, and attach the WS-MBO-POLE01 bracket to the pole.
  7. Tighten the cable clamp screw clockwise, tightening the band around the pole.