Assign an sFlow Receiver to a Switch Template

Before you can assign an sFlow receiver to a switch template, you must first configure an sFlow receiver as a common object. sFlow is not available for all Extreme switch models. See Configure an sFlow Receiver.

Use the following steps to assign sFlow receivers that you have configured as common objects to switch templates.
  1. Go to Configure > Common Objects > Policy > Switch Template.
  2. Select an existing switch template and then select Edit, or select Add, to create a new template.
  3. Select the sFlow Receivers tab.

    The sFlow Receivers feature is available only for supported switches.

  4. Type a Name for the template.
  5. Select Add,.
  6. Select a receiver object from the Available sFlow Receivers menu.
  7. Enable sFlow Receiver.
  8. Enable Interface Packet Sampling.
  9. Move interfaces you want to sample from the Available column to the Selected Interfaces column using the arrows.
  10. Enable Counter Polling.
  11. Move interfaces you want polled from the Available column to the Selected Interfaces column.
  12. Select Save.
  13. Select Save sFlow Receivers.