Temperature Operating Range
  
    On 
ExtremeSwitching series switches, if a switch runs outside the expected range, the
      switch logs an error message, generates a trap, and one of the following actions occurs:
        - On a SummitStack slots, the reset/none option from configure sys-recovery-level [all | none]
 command determines the action that
          occurs.
 
        - On ExtremeSwitching X430-8p
          switches, the device is shut down regardless of the recovery level, and after reboot you
          are prompted whether or not to boot the switch.
 
        - For all switches, other than the ExtremeSwitching X430-8p, only a warning is logged and the switch continues to run
          with the system state as "overheat." If the temperature increases further into overheat
          condition, after the operating temperature exceed a further higher temperature, the
          hardware resets the switch.