This section describes the procedure for configuring VMANs. Before
configuring VMANs, review Guidelines for Configuring VMANs. To configure a VMAN, complete the
following procedure at each switch that needs to support the VMAN:
-
If you are configuring a SummitStack, or
an ExtremeSwitching series switch, enable jumbo frames on the switch.
Note
You must enable jumbo
frames before configuring VMANs on these systems.
-
Create a VMAN using the command:
create vman
vman_name | vman_list vr vr_name
-
Assign a tag value to the VMAN using the command:.
configure
vman vman_name | vman_list
tag
tag_id
-
To configure PNP ports on a PEB or PB, use the following
command with the tagged option:
configure
vman vman_name | vman_id
add
ports [ all | port_list ] {untagged
{ port-cvid
port_cvid} | tagged}
-
To configure CNP ports on a PEB, use the following command
with the untagged option:
configure
vman vman_name
add
ports [ all | port_list ] {untagged
{ port-cvid
port_cvid} | tagged} Note
You must configure CNP ports as
untagged, so that the
S-tag is stripped from the frame on egress. If the
port-cvid is
configured, any untagged packet received on the port will be double tagged with the
configured port CVID and the SVID associated with the VMAN. Packets received with a
single CVID on the same port will still have the SVID added as usual. As double tagged
packets are received from tagged VMAN ports and forwarded to untagged VMAN ports,the
SVID associated with the VMAN is stripped. Additionally, the CVID associated with the
configured port CVID is also stripped in the same operation.
-
To configure CEP ports on a PEB, do the following:
-
Use the following command to establish a
physical port as a CEP and configure CVID mapping and translation:
configure vman vman_name | vman_id
add
ports
port_list
cep [ cvid <cvid or
cvid_range> { translate
<cvid or cvid_range> } } | port-cvid <port_cvid> ] }
-
Use the following commands to add or delete CVIDs
for a CEP and manage CVID mapping and translation:
configure vman vman_name | vman_id
ports
port_list
add
cvid {cvid | cvid_range} {translate
cvid | cvid_range }
configure vman vman_name
ports
port_list
delete
cvid {cvid |
cvid_range }
-
Use the following commands to manage CVID egress filtering
for a CEP:
enable
vman cep egress filtering ports {port_list |
all}
disable
vman cep egress filtering ports {port_list |
all}
-
Configure additional VMAN options as described in Configuring VMAN Options.
-
To configure a VLAN to use a
VMAN, configure the VLAN on the switch port at the other end of the line leading to the
VMAN access port.