Configuring FIB compression

Use the following procedure to enable FIB compression on the SLX 9540 and SLX 9640 devices.

  1. Enter hardware configuration mode.
    device# config
    device(config)# hardware
    device(config-hardware)# 
  2. Enable FIB compression by using the profile route route-enhance command as in the following example for both IPv4 and IPv6 compression.
    device(config-hardware)# profile route route-enhance v4_fib_comp v6_fib_comp on
    
  3. Confirm the configuration by using the show hw route-info command for an interface.
    device# show hw route-info interface 1/2
    
    HW-Route-Info
    ====================================================
    
    Slot 1
    
    Tower 0
    LEM
    Total Entries           :750000
    95% Threshold           :712500
    85% Threshold           :637500
    Total In Use            :39 (.000000%)
            IPV4  routes    :39
            IPV6  routes    :0
    Status                  :Green
    
    LPM
    Total Entries           :350000
    95% Threshold           :332500
    85% Threshold           :297500
    Total In Use            :331 (.000000%)
            IPV4  routes    :156
            IPV6  routes    :175
    Status                  :Green