Domain double-tagged support for CFM enables up and down MEP at a double-tagged provider edge. For a Bridge Domain double tagged port to advertise CFM, the CLI command must specify the inner VLAN while configuring the MEP using the mep command as follows.
For more information on the command, please refer the SLX-OS Command Reference guide.
The show cfm command displays the inner vlan-id for MEP as follows.
device# show cfm Domain: dom1 Level: 5 Maintenance association: ma1 MA Index: 4 CCM interval: 10000 ms Bridge-Domain ID: 100 Priority: 4 MEP Direction MAC PORT VLAN PORT-STATUS-TLV ==== ========= ========= ==== ======= =============== 11 DOWN 768e.f80a.9903 Eth 2/15 100,200 N
SLX# show cfm connectivity Domain: dom1 Level: 5 Maintenance association: ma1 MA Index: 4 CCM interval: 10000 Bridge-Domain ID: 100 Priority: 4 MAID Format: Short MEP Id: 2 MEP Port: Eth 1/5 RMEP MAC VLAN/PEER PORT STATE ==== === ========= ==== ===== 3 0010.9400.0002 100,200 Eth 1/5 OK