pluggable-optical-module
   
   
      Configure Digital Diagnostic Monitoring to get information concerning the status of the
         transmitted and received signals to allow better fault isolation and error detection.
    
      Syntax
         
         
            - 
               
                  default
                     pluggable-optical-module ddm-alarm-portdown 
                
- 
               
                  default
                     pluggable-optical-module ddm-monitor 
                
- 
               
                  default
                     pluggable-optical-module ddm-monitor-interval 
                
- 
               
                  default
                     pluggable-optical-module ddm-traps-send 
                
- 
               
                  no
                     pluggable-optical-module ddm-alarm-portdown 
                
- 
               
                  no
                     pluggable-optical-module ddm-monitor 
                
- 
               
                  no
                     pluggable-optical-module ddm-traps-send 
                
- 
               
                  pluggable-optical-module
                     ddm-alarm-portdown 
                
- 
               
                  pluggable-optical-module
                     ddm-monitor 
                
- 
               
                  pluggable-optical-module
                     ddm-monitor-interval <5-60> 
                
- 
               
                  pluggable-optical-module
                     ddm-traps-send 
                
- 
               
                  pluggable-optical-module
                     reset {slot/port[/sub-port]}
                
Command Parameters
         
         
            
               - ddm-alarm-portdown
- Sets the port down when an alarm
                  occurs. When enabled, the port goes down when any alarm occurs.
- ddm-monitor
- Enables the monitoring of the
                  digital diagnostic monitoring (DDM). When enabled, you see the internal
                  performance condition (temperature, voltage, bias, Tx power and Rx power) of the
                  pluggable transceiver. The default is disable.
- ddm-monitor-interval <5-60>
- Configures the digital diagnostic
                  monitoring (DDM) monitor interval in the range of 5 to 60 in seconds. If any alarm
                  occurs, the user gets the log message before the specific interval configured by
                  the user. The default value is 5 seconds.
- ddm-traps-send
- Enables or disables the sending of
                  trap messages. When enabled, the trap message is sent to the Device manager, any
                  time the alarm occurs. The default is enable.
- reset {slot/port[/sub-port]}
- Reset a transceiver to simulate
                  removal and reinsertion of the transceiver, which can be helpful in
                  troubleshooting. For example, if authentication of the transceiver fails, you can
                  reset the transceiver to begin the authentication process again. Before you use
                  this command, ensure the port is administratively down to avoid link flaps. 
- 
                  Identifies a
                                    single slot and port. If the platform supports channelization
                                    and the port is channelized, you must also specify the sub-port
                                    in the format slot/port/sub-port. 
Default
         
         The default is disable.
      
      Command Mode
         
         Global Configuration