Display isis spbm related info.
show isis spbm
None
User EXEC
The show isis spbm command displays the following information:
| Output field | Description | 
|---|---|
| SPBM INSTANCE | Indicates the SPBM instance identifier. You can only create one SPBM instance. | 
| B-VID | Indicates the SPBM B-VLAN associated with the SPBM instance. | 
| PRIMARY VLAN | Indicates the primary SPBM B-VLAN. | 
| NICK NAME | Indicates the SPBM node nickname. The nickname is used to calculate the I-SID multicast MAC address. | 
| LSDB TRAP | Indicates the status of the IS-IS SPBM LSDB update trap on this SPBM instance. The default is disable. | 
| IP | Indicates the status of SPBM IP shortcuts on this SPBM instance. The default is disable. | 
| IPv6 | Indicates the status of SPBM IPv6 shortcuts on this SPBM instance. The default is disable. | 
| MULTICAST | Indicates if SPBM multicast is enabled. The default is disabled. | 
| SPB-PIM-GW | Indicates if SPB PIM Gateway is enabled. The default is disabled. | 
| STP-MULTI HOMING | Indicates if MSTP-Fabric Connect Multi Homing is enabled. The default is disabled. | 
| SMLT-SPLIT-BEB | Specifies whether the switch is the primary or secondary vIST peer. | 
| SMLT-VIRTUAL-BMAC | Specifies a virtual MAC address that can be used by both peers. | 
| SMLT-PEER-SYSTEM-ID | Specifies the vIST peer system ID. |