trigger-function
Syntax
trigger-function
{
OR
|
AND
time-window
seconds
}
Command Default
The event-handler action runs if any of the triggers occur.
Parameters
- OR
- The event-handler action runs if any of the triggers occur.
- AND
- The event-handler action runs only if all of the triggers occur.
- time-window
seconds
- In seconds, specify the time window within which all of the triggers must occur in order that the event-handler action runs.
Following an initial triggering of an event-handler action, any subsequent trigger launches the action an additional time if the following conditions are true:
- The
trigger-mode parameter is set to the default
each-instance.
- The subsequent trigger occurs within the specified
time-window.
Modes
Event-handler activation mode
Usage Guidelines
The
no form of this command sets the
trigger-function setting to the default
OR option.
Examples
The following example determines that the event-handler action runs only if all of the triggers occur within 120 seconds.
device# configure terminal
device(config)# event-handler activate eventHandler1
device(config-activate-eventHandler1)# trigger-function AND time-window 120
The following example resets
trigger-function to the default
OR option.
device# configure terminal
device(config)# event-handler activate eventHandler1
device(config-activate-eventHandler1)# no trigger-function