ccm-interval
Sets the time interval between two successive Continuity Check Messages (CCMs) that are sent by Maintenance End Points (MEP) in the specified Maintenance Association (MA).
Syntax
ccm-interval
[1-second
| 10-second
| 3.3-ms
| 10-ms
| 100-ms
]
Parameters
- 1-second
- Sets the time interval between two successive CCM packets to 1 second.
- 10-second
- Sets the time interval between two successive CCM packets to 10 seconds.
- 3.3-ms
- Ssets the time interval between two successive CCM packets to 3.3 milliseconds.
- 10-ms
- Sets the time interval between two successive CCM packets to 10 milliseconds.
- 100-ms
- Sets the time interval between two successive CCM packets to 100 milliseconds.
Modes
CFM protocol configuration mode
Usage Guidelines
The default value is 10 seconds.
Examples
device# configure terminal
device(config)# protocol cfm
device(config-cfm)# domain name md1 level 4
device(config-cfm-md-md1)# ma-name ma1 id 1 vlan-id 30 priority 4
device(config-cfm-md-ma-ma1)#ccm-interval 10-second