threshold-monitor Cpu
Configures monitoring of CPU usage of the system and alerts the user when configured
thresholds are exceeded.
Syntax
threshold-monitor Cpu
{
[
actions
[
all
|
loginfo
|
none
|
raslog
|
snmp
]
]
|
limit
value-in-percentage
|
poll
polling-interval
|
retry
retry-interval
}
Parameters
-
actions
- Specifies the action to be taken when a threshold is exceeded. The values
supported are
all
, loginfo
,
none
, raslog
, and
snmp
where snmp
and
all
are newly added. Default "action
"
is changed to "all
".
-
all
- RASLOG and SNMP trap will be sent when the threshold is
exceeded.
-
loginfo
- Additional diagnostics data will be collected along with RASLOG
when the threshold is exceeded.
-
none
- No action will be taken when the threshold is exceeded.
-
raslog
- Only RASLOG will be sent when the threshold is exceeded.
-
snmp
- SNMP traps will be sent when the threshold is exceeded.
-
limit
value-in-percentage
- Specifies the baseline CPU usage limit as a percentage (%) of available
resources that will trigger the configured action. The range is 0%-95%. The
default value is 50%.
-
poll
polling-interval
- Specifies the polling interval in seconds after which a sample will be
taken. The range is 10-3600 seconds. The default interval is 120 seconds.
-
retry
retry-interval
- Specifies the number polling retries that will be attempted before desired
action is taken. The range is 1-100. The default retries is 3.
Modes
Global configuration mode
Usage Guidelines
The default action
is all. Prior to SLXOS version 20.4.1,
the default value was none.
Examples
SLX(config)# threshold-monitor Cpu ?
Possible completions:
actions Action to be taken when usage exceeds limit
limit PERCENT:0-95 Percent threshold usage for component:CPU
poll NUMBER:10-3600 Polling interval
retry NUMBER:1-100 Number of retries
SLX(config)#
This example details on threshold-monitor cpu actions.
SLX(config)# threshold-monitor cpu actions ?
Possible completions:
[none]
all RASLOG and SNMP trap will be sent
loginfo Diagnostic data collection along with RASLOG
none No action will be taken
raslog RASLOG will be sent
snmp SNMP trap will be sent
SLX(config)#