configure cfm segment frame-loss window
Description
This command is used to configure the window size for calculating the alarm/clear threshold values for DMM and Severely Errored Second (SES) threshold for LMM. This window size denotes the total number of recent frames for which the threshold values will be measured.
If the optional keyword frame-delay or frame-loss is not specified, the same value of window size will be used for both DMM and LMM. The optional keyword allows configuring values for DMM and LMM.
Syntax Description
segment_name |
Alphanumeric string identifying the segment name. |
frame-loss |
Y.1731 Ethernet frame loss measurement. |
window_size |
Window size for loss measurement; number of frames 1-1800 to be used. |
Default
1200.
Usage Guidelines
Use this command to configure the window size for calculating the alarm/clear threshold values for DMM and Severely Errored Second (SES) threshold for LMM.
Example
configure cfm segment cs2 frame-loss window 900
History
This command was first available in ExtremeXOS 15.1.
Platform Availability