Configuring a CFM Segment

Use the following commands to configure a CFM segment.

Some of these commands are optional and, if not configured, the default values are used. Default Values for Delay Measurement for a CFM Segment lists the default values for delay measurement for a CFM segment.

Table 1. Default Values for Delay Measurement for a CFM Segment
Configuration Default Values
Transmit interval 10 seconds
Window 60 frames
Timeout 50 milliseconds
Alarm threshold 10%
Clear threshold 95%
Dot1p priority 6

Default Values for Loss Measurement for a CFM Segment lists the default values for loss measurement for a CFM segment.

Table 2. Default Values for Loss Measurement for a CFM Segment
Configuration Default Values
LMM Transmit interval 90 seconds
Dot1p priority 6
Window 1200 frames
SES threshold 0.01
Consecutive available count 4
Note

Note

The statistics for a particular transmission are preserved until the user triggers the transmission once again or if clear counters cfm segment is triggered from the CLI.