Message:sFlow is <state> globally.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow is enabled or disabled globally.
Recommended Action: No action is required.
Message: sFlow is <state> for port <name>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow is enabled or disabled on the specified port.
Recommended Action: No action is required.
Message: Global sFlow sampling rate is changed to <sample_rate>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the global sFlow sampling rate has been changed to the specified value.
Recommended Action: No action is required.
Message: Global sFlow polling interval is changed to <polling_intvl>.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates that the global counter sampling interval has been changed to the specified value.
Recommended Action: No action is required.
Message: sFlow sampling rate on port <name> is changed to <sample_rate>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that the sFlow sampling rate has been changed on the specified port.
Recommended Action: No action is required.
Message: sFlow polling interval on port <name> is changed to <poling_intvl>.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates that the sFlow polling interval has been changed on the specified port.
Recommended Action: No action is required.
Message: <name> is <state> as sFlow collector.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates that the specified sFlow collector is either configured or not configured.
Recommended Action: No action is required.
Message: All the sFlow collectors are unconfigured.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that none of the sFlow collectors are configured.
Recommended Action: No action is required.
Message: Socket Operation Failed while connecting with the collector address.
Message Type: DCE
Severity:WARNING
Probable Cause:Indicates that the connection to the sFlow collector server failed.
Recommended Action: Reconfigure the sFlow collector using the sflow collector command.
Message: sFlow profile is created with name <name> and sampling rate <sample_rate>.
Message Type: DCE
Severity:INFO
Probable Cause: Indicates that the specified sFlow profile has been created.
Recommended Action: No action is required.
Message: sFlow profile with name <name> is deleted.
Message Type: DCE
Severity:INFO
Probable Cause:Indicates that the specified sFlow profile has been deleted.
Recommended Action: No action is required.
Message: sFlow profile with name <name> is updated with sampling rate <sample_rate>.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates that the sampling rate has been updated for the specified sFlow profile.
Recommended Action: No action is required.
Message: sFlow profile with name <name> is in use. Cannot be deleted.
Message Type: DCE
Severity:WARNING
Probable Cause:Indicates that the specified sFlow profile is in use and therefore it cannot be deleted.
Recommended Action: No action is required.
Message: <message>.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates the sFlow configuration details.
Recommended Action: No action is required.
Message: Max no. of profiles (<message>) already configured.
Message Type: DCE
Severity: INFO
Probable Cause:Indicates the sFlow configuration details.
Recommended Action: No action is required.
Message: sFlow Collector VRF is changed to <vrf_name>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow collector VRF has been changed to the specified value.
Recommended Action: No action is required.
Message: sFlow null0 sampling is <state> globally.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow null0 sampling is enabled or disabled globally.
Recommended Action: No action is required.
Message: sFlow SourceIP Interface is changed to <srcIpIfTypeStr> <srcIpIfNumStr> (<srcIpIfOsName>).
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow SourceIP Interface has been changed to the specified value.
Recommended Action: No action is required.
Message: sFlow Agent address is changed to <agentAddrTypeStr>, Intf: <agentAddrIfTypeStr> <agentAddrIfNumStr> (<agentAddrIfOsName>).
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that sFlow Agent address has been changed to the specified value.
Recommended Action: No action is required.
Message: App-telemetry is <state> with sFlow collector <collectorIpPortVrfStr>.
Message Type: DCE
Severity: INFO
Probable Cause: Indicates that App-telemetry is enabled or disabled globally.
Recommended Action: No action is required.